1. GENERAL INSTRUCTIONS
Carefully read the instructions contained in this instruction booklet.
After boiler installation, inform the user regarding its operation and give him this
manual, which is an integral and essential part of the product and must be kept with
care for future reference.
Installation and maintenance must be carried out by professionally qualified person-
nel, according to current regulations and the manufacturer's instructions. Do not car-
ry out any operation on the sealed control parts.
Incorrect installation or inadequate maintenance can result in damage or injury. The
Manufacturer declines any liability for damage due to errors in installation and use
or failure to follow the instructions.
Before carrying out any cleaning or maintenance operation, disconnect the unit from
the power supply using the system switch and/or the special cut-off devices.
In case of a fault and/or poor operation, deactivate the unit and do not attempt to
repair it or directly intervene. Contact professionally qualified personnel. Repair/re-
placement of the products must only be carried out by professionally qualified using
original spare parts. Failure to comply with the above could affect the safety of the
unit.
This unit must only be used for its intended purpose. Any other use is considered
improper and therefore dangerous.
The packing materials are potentially hazardous and must not be left within the
reach of children.
The images given in this manual are a simplified representation of the product. In
this representation there may be slight and insignificant differences with respect to
the product supplied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
ECONCEPT TECH 10 A is a high-efficiency, low emissions sealed chamber premix
condensing heat generator for heating and hot water production (with optional external
hot water storage tank), running on natural gas or LPG and equipped with a microproc-
essor control system.
The sealed chamber unit is suitable for indoor installation or outdoors in a partially pro-
tected place (according to EN 297/A6) with temperatures to -5°C (-15°C with optional
trap antifreeze kit).
The boiler is arranged for connection to an external hot water storage tank (optional).
In this manual all the functions relevant to domestic hot water production are only active
with the optional hot water tank connected as indicated in sec. 3.3.

2.2 Control panel

1
9
10
11
12
3
13
fig. 1 - Control panel
Key
1 =
Domestic hot water temperature setting
3 =
Heating system temperature setting
5 =
Display
6 =
"Sliding Temperature" Menu - Summer/Winter mode selection - Reset button
7 =
Unit On/Off - Eco/Comfort mode selection button
9 =
DHW mode
10 =
Summer mode
11 =
Multifunction (blinking during the exchanger protection function)
12 =
Eco (Economy) mode
13 =
Heating
15 =
Burner On and actual power (blinking during the flame protection function)
26
EN
5
15
7
eco
comfort
reset
6
cod. 3540T631 - 01/2011 (Rev. 00)
ECONCEPT TECH 10 A
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display.
The display (detail 11 - fig. 1) shows the actual heating delivery temperature and, during
heating standby time, the message "d2".
Domestic hot water (DHW)
A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display.
The display (detail 11 - fig. 1) shows the actual DHW outlet temperature and, during
DHW standby time, the message "d1".
Comfort
A Comfort demand (reinstatement of temperature inside the boiler) is indicated by flash-
ing of the water under the tap on the display. The display (detail 11 - fig. 1) shows the
actual temperature of the water in the boiler.

2.3 Lighting and turning off

Connection to the power supply
During the first 5 seconds the display shows the card software version.
Open the gas cock ahead of the boiler.
The boiler is now ready to operate automatically whenever hot water is drawn or in
case of a room thermostat demand.
Boiler lighting and shutdown
Press the on/off button (detail 7 - fig. 1) for 5 seconds.
fig. 2 - Turning the boiler off
When the boiler is turned off, the PCB is still powered. Domestic hot water and heating
are disabled. The antifreeze system remains activated. To relight the boiler, press the
on/off button (detail 7 fig. 1) again for 5 seconds.
The boiler will be immediately ready to operate whenever domestic hot water is drawn
or in case of a room thermostat demand.
B
The antifreeze system does not work when the power and/or gas to the unit are
turned off. To avoid damage caused by freezing during long idle periods in win-
ter, it is advisable to drain all water from the boiler, DHW circuit and system; or
drain just the DHW circuit and add a suitable antifreeze to the heating system,
complying with that prescribed in sec. 3.3.
2.4 Adjustments
Summer/Winter Switchover
Press the summer/winter button (detail 6 - fig. 1) for 2 seconds.
The display activates the Summer symbol (detail 10 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.
To deactivate the Summer mode, press the summer/winter button (detail 6 - fig. 1)
again for 2 seconds.
Heating temperature setting
Use the heating buttons (detail 3 - fig. 1) to adjust the temperature from a min. of 20°C
to a max. of 90°C.
DHW temperature adjustment
Use the DHW buttons (detail 1 - fig. 1 ) to adjust the temperature from a min. of 10°C to
a max. of 65°C.
fig. 3
fig. 4
fig. 5