MISC. SETUP SUBMENU- Sets a series of system options.
• Input Select- Choose the inputs which STAGEDRIVE+ should use, digital or analog.
• Output Meters- Choose whether to display the output signal before or after MUTE.
The options include:
PreMute- the signal is always shown no matter what the MUTE status
PostMute- the signal is only shown if the output is not in MUTE
• Temperature- Sets the value of the environmental temperature at the place of installation to compensate
for differentials due to the varying speed of sound transmission due to the air temperature. The editing
values are in the following ranges: +60 C ~ -30 C with 1 C steps 140.0 F ~ -22.0 F with 1.8 F steps
Note: The measurement units can be chosen between C (degrees Centigrade) and F (degrees
Fahrenheit) by means of the Temperature Unit function (UTILITY menu - Units submenu).
• Wake Up- Sets the mode in which MUTE functions are restored when the STAGEDRIVE+ is switched on.
The options include:
Normal- When switched on, the system restores the last MUTE configuration before switching off
Mute- When switched on, the system automatically sets all the outputs in MUTE
15