OPERATION INSTRUCTIONS
3.
If it is necessary to remove the faucet (A),
gently press the button (1) and lift the faucet (A)
vertically upwards.
CARE AND MAINTENANCE
• Clean carefully by gently wiping with a grit-free damp cloth.
• Use only mild soap with water.
• Never use acids, harsh chemicals, or abrasive detergents to clean the faucet surface.
TROUBLESHOOTING
PROBLEM
There are leaks
underneath the handle.
The aerator leaks or has
an inconsistent
water flow pattern.
There are leaks from the
hose underneath the
deck.
The hose does not
retract.
POSSIBLE CAUSE
The bonnet nut has come loose and
the O-ring on the cartridge is dirty or
damaged.
1. The aerator is dirty or misfitted.
2. The cartridge may be clogged.
The hose and discharge tube
connection may be loose.
The weight is not installed in the
appropriate position.
3
CORRECTIVE ACTION
Tighten the bonnet nut. Clean or
replace the O-ring.
1. Remove the aerator and check
for debris in the aerator screens.
2. Remove the cartridge and check
for debris.
3. Ensure the aerator is properly
installed.
Tighten the connection between
the discharge tube and hose.
Reinstall or readjust the weight.
8