tURNINg OFF tHe ReFRIgeRAtOR
If the refrigerator is not to be used for some time:
1.
Shut off any valve in the gas line to the refrigerator.
2.
Set the energy selector (A) to 0.
3.
Empty the refrigerator. Defrost and clean it as described
earlier. Leave the doors of the refrigerator and the frozen
food compartment ajar.
IF tHe 'FRIDge FAILs tO WORK
Check the following points before calling a service techni-
cian:
1.
That the STARTING THE REFRIGERATOR instructions
have been followed.
2.
The refrigerator is leveled.
3.
If it is possible to start the refrigerator on any of the con-
nected sources of energy.
4.
If the refrigerator fails to work on gas, check:
•
That the gas bottle is not empty.
•
That all LP-gas valves are open.
5.
If the refrigerator fails to work on mains electric, check:
•
That the mains electric supply is connected to the
refrigerator.
•
That the fuse is intact.
If the refrigerator is not cold enough it may be
because:
1.
The ventilation of the cooling unit is inadequate; see the
paragraph PLACEMENT OF THE REFRIGERATOR.
2.
The evaporator is frosted up.
3.
The temperature control setting is incorrect.
4.
The gas pressure is incorrect - check the pressure regulator
at the gas container.
5.
The door is not properly closed or the magnetic sealing
strip is defective.
If the refrigerator still does not work properly, call a service
technician.
The sealed cooling system must not be opened,
since it contains corroding chemicals under
high pressure.
MAINteNANCe
Inspect the gas hose periodically for cracks or deep chaf-
ing marks. Connections can be tested for leaks using a soap
solution. DO NOT USE AN OPEN FLAME! If there is any
suspicion of damage, call for a service technician. We recom-
mend that a service technician check the refrigerator once a
year.
sOMe UseFUL HINts
Make sure that:
•
Defrosting is carried out periodically.
•
The refrigerator is clean and dry with the door left open
when it is not to be used for some time.
•
Liquids or items with a strong odour are well packaged.
•
There is a free air circulation over the cooling unit at the
rear of the refrigerator.
teCHNICAL DAtA
Overall dimensions
Height
Width
Depth
Capacity
Gross, total
Freezer
Weight (without packaging)
Electrical data
Input 120, 230, 240 V
Energy consumption/24h
LP gas data
Input max
Cooling medium
Sodium chromate is used for corrosion protection (less than
2 weight % of the coolant).
INstALLAtION INstRUCtIONs
This appliance must be installed by an authorised person
and conform to all relevant authorities.
PLACeMeNt OF tHe ReFRIgeRAtOR
The room should have a capacity (length x width x height)
of at least 20 m
and must be adequately ventilated as well as
3
follow all relevant national and local regulations. Further the
room should have a window (which can be opened) or a door
to the outside.
It is important that the refrigerator is not subject to radiation
of heat from a stove etc.
For best performance also at high ambient temperatures there
must be a free air circulation over the cooling unit at the rear
of the refrigerator.
The refrigerator is designed for a free-standing installation
and the clearance to the rear wall and to possible side walls,
should be at least 25 mm. The clearance above the refrigera-
tor should be at least 100 mm.
The refrigerator must be adjusted to a vertical position in both
directions, see bubble level at the bottom of the refrigerator.
Use the feet on the refrigerator to adjust its position.
From the side
At least
25 mm
5
V110 GE
V170 GE
1019
1456 mm
592
592 mm
623
623 mm
110
185 litres
15
47 litres
52
68 kg
175
300 watt
2.2
3.9 kWh
0.33
0.48 kW
Ammonia
From above
Wall
25
Wall