E L E V A T I N G C U L I N A R Y E X C E L L E N C E
MAINTENANCE
MINIMAX – MINIMATIC
Remove the positioner, pushing it upwards.
Remove the knife, by unscrewing the knife screw
(Be careful. The knife is sharp). Remove the
squeezer male part, by unscrewing the screw.
Remove the squeezer drum by unscrewing the
screw. Remove the second squeezer male part.
Remove the ejector.
For the models with head feeder: Take of the
turning feeder plate, by unscrewing the screw.
TOP/FAST TOP
Unscrew the five principal screws of the squeezing system parts.
Remove the two squeezing drums, the two male
parts and knifepiece pulling it outwards. Be
careful with this part, because of its cutting edge.
For the models with the upper feeder component,
twist softly the upper metal basket all the way
towards the left and then gently pull up. Remove
the turning dish by unscrewing the screw towards
the right.
Thoroughly clean all parts, and block of the machine with cold water and
detergent.
Do not use abrasive nor corrosive products, since they could harm the compound
of the elements of the machine. Do not clean the machine with water under
Page 12 / 52