Do not ground to a gas pipe.
•
Check with a qualified electrician if you are not sure the
washer is properly grounded.
•
Do not have a fuse in the neutral or ground circuit.
Electrical
Shock Hazard
Pmuginto a grounded
3 prong outlet.
Do not remove ground
prong,
Do not use an adapter.
Do not use an extension
cord.
Failure to follow
these instructions
can resumt in death,
fire, or e_ectdcam shock,
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is recommended
that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having a
3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type
outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.
GROUNDmNG
INSTRUCTIONS
For a grounded,
cord-connected
washer:
This washer must be grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk of electricaI
shock by providing a path of least resistance for electric
current. This washer is equipped with a cord having an
equipment-grounding
conductor and a grounding plug. The
plug must be pIugged into an appropriate outlet that is
properly installed and grounded in accordance with aII IocaI
codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly grounded.
Do not modify' the plug provided with the appliance - if it wilI
not fit the outlet, have a proper outlet installed by a qualified
electrician.
For a permanentmy connected
washer:
This washer must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding
terminal or lead on
the appliance.