AVENTICS specific
Index dec
Name
Format
(hex)
(offset)
391
Qa analog value
UInt
(0x187)
simulation
400
Q2 analog mode UInt
(0x190)
403
Q2 analog polar-
UInt
(0x193)
ity
404
Q2 upper analog
Float
(0x194)
value (20mA)
405
Q2 lower analog
Float
(0x195)
value (4mA)
406
Q2 analog signal
String
(0x196)
unit and range
410
Q2 analog value
UInt
(0x19A)
in case of error
411
Q2 analog value
UInt
(0x19B)
simulation
420
Display unit
UInt
(0x1A4)
mass flow
421
Display unit gas
UInt
(0x1A5)
speed
422
Display unit vol-
UInt
(0x1A6)
ume
423
Display unit vol-
UInt
(0x1A7)
ume flow
424
Display unit
UInt
(0x1A8)
mass
425
Display unit en-
UInt
(0x1A9)
ergy
426
Display unit tem-
UInt
(0x1AA)
perature
427
Display unit
UInt
(0x1AB)
pressure
428
Switch off dis-
UInt
(0x1AC)
play
AVENTICS™ IO-Link AF2 | R412027828-BAL-001-AC | English
Lengt
Ac-
Default value
Value
h
cess
range
8 bits
rw
255
35 = 3.5mA
38 = 3.8mA
40 = 4.0mA
100 = 10mA
120 = 12mA
180 = 18mA
200 = 20mA
205 = 20.5mA
215 = 21.5mA
255 =
simulation off
8 bits
rw
0 = 4-20mA volume flow
1 = 4-20mA pressure
2 = 4-20mA temperature
8 bits
rw
0 = normal
1 = inverted signal
4
rw
- 30.0 ... 999
See index 406
bytes
9.0
4
rw
- 30.0 ... 999
See index 406
bytes
9.0
32
ro
Unit and range for index 404 and 405
bytes
8 bits
rw
0 = 3.5mA
1 = 21.5mA
8 bits
rw
255
35 = 3.5mA
38 = 3.8mA
40 = 4.0mA
100 = 10mA
120 = 12mA
180 = 18mA
200 = 20mA
205 = 20.5mA
215 = 21.5mA
255 = simulation
off
8 bits
rw
0 = kg/h
1 = g/s
2 = kg/min
8 bits
rw
0 = m/s
1 = fps
8 bits
rw
0 = m³
1 = l
2 = ft³
8 bits
rw
0 = m³/h
1 = m³/min
2 = l/s
3 = l/min
4 = ft³/s
5 = ft³/min
8 bits
rw
0 = kg
8 bits
rw
0 = kWh
8 bits
rw
0 = °C
1 = °F
8 bits
rw
0 = bar
1 = psi
8 bits
rw
0 = off
1 = 1min
2 = 2min
5 = 5min
10 = 10min
30 = 30min
60 = 60min
AVENTICS specific
Com-
Index dec
Name
ment
(hex)
[unit]
429
Rotate display
(0x1AD)
430
Screensaver
(0x1AE)
431
Display bright-
(0x1AF)
ness
432
Display pin
(0x1B0)
433
Display 1 top
(0x1B1)
434
Display 1 bot-
(0x1B2)
tom
435
Display 2 top
(0x1B3)
436
Display 2 bot-
(0x1B4)
tom
437
Display 3 top
(0x1B5)
Format
Lengt
Ac-
Default value
(offset)
h
cess
UInt
8 bits
rw
0 = 0°
1 = 90°
2 = 180°
3 = 270°
UInt
8 bits
rw
0 = off
1 = 1min
2 = 2min
5 = 5min
10 = 10min
30 = 30min
60 = 60min
UInt
8 bits
rw
2 = 40%
7 = 60%
10 = 80%
15 = 100%
UInt
16 bits rw
0 ... 9999
UInt
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
UInt
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
UInt
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
UInt
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
UInt
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
Value
Com-
range
ment
[unit]
Pin to protect the
configuration,
0000 ==> no pin
assigned
11