Frequency Band
ETSI & India
SLA-R41-A/U04-xx: TTL
865 - 868 MHz
SLA-R42-A/U04-5AB: RS232
ERP: 2W
SLA-R43-A/U04-7AB: RS485
SLA-W43-A/U04-7OS: OSDP™ v1 & v2 - RS485
SLA-W42-A/U04-5AX: SSCP
SLA-W43-A/U04-7AX: SSCP
FCC and ISED PMN
SLA-R51-A/U04-xx: TTL
902 - 928 MHz
SLA-R52-A/U04-5AB: RS232
EIRP: 4W
SLA-R53-A/U04-7AB: RS485
SLA-W53-A/U04-7OS: OSDP™ v1 & v2 - RS485
SLA-W52-A/U04-5AX: SSCP
SLA-W53-A/U04-7AX: SSCP
Peru
SLA-R51-A/U04-xx1PE: TTL
916 - 928 MHz
SLA-R52-A/U04-5AB1PE: RS232
EIRP: 4W
SLA-R53-A/U04-7AB1PE: RS485
SLA-W53-A/U04-7OS1PE: OSDP™ v1 & v2 - RS485
SLA-W42-A/U04-5AX1PE: SSCP
SLA-W43-A/U04-7AX1PE: SSCP
New-Zealand
SLA-R51-A/U04-xx1NZ: TTL
922 - 928 MHz
SLA-R52-A/U04-5AB1NZ: RS232
EIRP: 4W
SLA-R53-A/U04-7AB1NZ: RS485
SLA-W53-A/U04-7OS1NZ: OSDP™ v1 & v2 - RS485
SLA-W42-A/U04-5AX1NZ: SSCP
SLA-W43-A/U04-7AX1NZ: SSCP
Use an AC/DC power supply LPS type, Limited Power Source (as per IEC EN 60950-1 Ed2) or ES1 type, PS1 (as per IEC EN 62368-1) for main supply and for an
eventual V+/V-.
Main power supply:
Range +9 Vdc up to +36 Vdc
Advice:
To overcome the cable length effect on the supply voltage seen by the reader, it's recommended to use a 24V power supply
Consumption:
Typical: 1A under +12 Vdc
Communication:
TTL (Wiegand / Clock & Data)
Pin out:
Temperature:
Protection:
Chip:
I/O:
Module LED:
Antenna LED:
RS485:
Use a multi-conductor shielded twisted
RS232:
pair cable - Max length 49.21 ft / 15 m.
Use a multi-conductor shielded untwisted
2 cable AWG24 – 30 m / 98.4 ft max
4 cables AWG24 – 60 m / 196.9 ft max
Wiegand /
Clock & Data:
6 cables AWG24 – 100 m / 328.1 ft max
2 cable AWG20 – 50 m / 164. ft max
4 cables AWG20 – 100 m / 328.1 ft max
Install the reader away from computer transmission cables or from power sources (ex: RJ45, AC power line...).
The disruptions that they can cause can vary according to their radiation power and their proximity.
Use a filtered and regulated power supply.
Antennas connected to different readers may interfere with each other. Move them away from each other.
A power supply which provides 1.5 A min under +12Vdc is recommended.
If the IN/OUT are powered by the module, use a 2A min under +12Vdc power supply.
Users must not remain within a range of less than, 34 cm / 13.39 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
Only the hatch can be opened.
Before any service operation you must de-energize reader.
Check that the hatch seal is correctly positioned before closing.
Do not remove the caps of unused
cable glands:
Careful: There is a 5.5 volts DC on each RF port.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1132X01 - Page 1 sur 24 - Ed. 21/02/2024
STid reserves the right to make change without notice, for the purpose of product improvement.
SPECTRE Access UHF
Installation procedure
References
v1 & v2 - RS232
®
v1 & v2 - RS485
®
v1 & v2 - RS232
®
v1 & v2 - RS485
®
®
v1 & v2 - RS232
®
v1 & v2 - RS485
v1 & v2 - RS232
®
®
v1 & v2 - RS485
Typical: 12 Vdc
Max: 1.5A under +12 Vdc
Read-only
RS485 (L+ & L-) / RS232 (Tx)
1 red LED: presence of power supply and 1 green LED: activity on Reader / host link
7 configurable colors (red, green, blue, orange, purple, turquoise, white)
Read-only
Use a multi-conductor shielded twisted pair cable - Max length 3 280 ft / 1000 m at 9600 baud.
Do not remove the caps from the
unused RF connectors:
UHF SPECTRE Access
Notice d'installation
Frequency Band
Morocco
865.7 MHz
ERP: 2W
Philippines
918 - 920 MHz
EIRP: 4W
Australia
920 - 926 MHz
EIRP: 4W
Power Supply Characteristics
Characteristics
OSDP
TM
RS485 (L+ & L-)
Terminal block plug 3x4 pins and 1x8 pins, thread 3.81 mm / 0.149 in
-25 to +60 °C / -13 to +140 °F
IK10 certified Reader casing - IP66
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
4 optocoupled inputs and 4 optocoupled outputs
Recommended Cables
OSDP
TM
--
--
Recommendations
UHF SPECTRE Access
Manual de instalación
References
SLA-R41-A/U04-xx1M: TTL
SLA-R42-A/U04-5AB1M: RS232
SLA-R43-A/U04-7AB1M: RS485
SLA-W53-A/U04-7OS1M: OSDP™ v1 & v2 - RS485
SLA-W42-A/U04-5AX1M: SSCP
SLA-W43-A/U04-7AX1M: SSCP
SLA-R51-A/U04-xx1PH: TTL
SLA-R52-A/U04-5AB1PH: RS232
SLA-R53-A/U04-7AB1PH: RS485
SLA-W53-A/U04-7OS1PH: OSDP™ v1 & v2 - RS485
SLA-W42-A/U04-5AX1PH: SSCP
SLA-W43-A/U04-7AX1PH: SSCP
SLA-R51-A/U04-xx1AU: TTL
SLA-R52-A/U04-5AB1AU: RS232
SLA-R53-A/U04-7AB1AU: RS485
SLA-W53-A/U04-7OS1AU: OSDP™ v1 & v2 - RS485
SLA-W42-A/U04-5AX1AU: SSCP
SLA-W43-A/U04-7AX1AU: SSCP
RS485 (L+ & L-) / RS232 (Tx & Rx)
Use a multi-conductor shielded twisted
pair cable - Max length 49.21 ft / 15 m.
Install the reader with the word UP facing
upwards in that way the connectors are down:
US
FR
ES
v1 & v2 - RS232
®
v1 & v2 - RS485
®
v1 & v2 - RS232
®
v1 & v2 - RS485
®
®
v1 & v2 - RS232
®
v1 & v2 - RS485