To turn on the roller bars:
Press the roller bar ON/OFF button again to turn the roller
bar back on.
NOTE: If vacuum is turned off while the roller bar is off, when
the vacuum is turned back on, the roller bar will default to
the ON setting.
LED INDICATOR FUNCTIONS
See Figure 3, page 8.
The LED will indicate the status of the tool when the tool is
powered on.
TOOL STATUS
HANDLE LED
High
Medium
Low
FAULT STATUS
HANDLE LED
Low Battery
Flashing Red
Clog / dirty filter
All 3 Flashing
Roller Bar OCP
USING THE FLOOR HEAD
See Figure 4, page 9
The floor head can connect directly to the vacuum for clean-
ing upholstery and stairs or attach with the extention wand
for normal floor vacuuming.
To connect:
Turn off unit and remove the battery pack.
Align the pins on the floor head with the receptacle in the
vacuum console or extension wand.
Press together until it clicks into place.
Replace battery pack.
To remove:
Turn off the unit and remove the battery pack.
Depress locking tab and pull to remove.
ATTACHING AND REMOVING THE EXTENSION
WAND AND ACCESSORY TOOLS
See Figure 5, page 9
The extension wand and accessories can be used together
or separately for a variety of cleaning tasks.
To connect:
Turn off the unit and remove the battery pack.
For the extension wand, align the pins on the extension
wand with the receptacle in the vacuum console.
Press together until it clicks into place.
ROLLER BAR
LED
All 3 Green
White
1 & 2 Green
White
1 Green
White
ROLLER BAR
LED
White
White
Red
-
OPERATION
For accessories, insert into the outlet of the stick vacuum
or the extension wand.
Press together until it fits securely.
Replace battery pack.
To remove:
Turn off the unit and remove the battery pack.
Depress locking tab and pull to remove.
REMOVING/EMPTYING/REATTACHING THE
DUST BOWL
See Figures 6 - 8, page 9.
The dust bowl should be checked, emptied, and cleaned
periodically for maximum dust collection.
To remove and empty:
Remove the battery pack.
Pull the dust bowl handle out and away to remove the
dust bowl assembly from the vacuum console.
Hold dust bowl assembly over waste receptacle.
Press the latch on bottom of bowl to release door.
Shake lightly or tap sides to dislodge debris.
Close door, pressing firmly until lock tab engages.
To reattach:
Red
Position the two sections as shown.
Align the hooks on the bottom of dust bowl with the hinge
point on the bottom of vacuum console.
Rotate the dust bowl upward to align the locking tabs
with the locking pins on the vacuum console.
Push the dust bowl toward the vacuum console until it
locks into place.
REMOVING BLOCKAGES AND CLEANING
THE FLOOR HEAD
See Figure 9, page 10.
Obstructions in the floor head may activate the overload
protection sensor and must be removed. The floor head will
stop and the light on the floor head illuminates red.
To reset:
Remove the battery pack.
Remove the floor head from the wand or vacuum console
and clear any obstructions.
Wait at least 1 minute before inserting the battery and
powering on the tool.
6 — English