• If there is a risk of flooding, fit the plug connec-
tions in the flood-proof area.
• Ensure that the mains voltage corresponds to the
specifications on the type plate.
• Carry out the electrical installation in accordance
with national regulations.
• Only connect the device to a mains socket with a re-
sidual current device (RCD) with a rated leakage cur-
rent of no more than 30 mA; fuse at least 6 amps.
• Before each use, check the device, cables and con-
nectors for damage. Defective cables must not be
repaired but replaced with a new ones. Have dam-
age to your device repaired by a specialist.
• If the connection cable of this unit is damaged, it
must be replaced by the manufacturer or their ser-
vice department or a similar qualified person in or-
der to avoid hazards.
• Do not use the cable to pull the plug out of the outlet.
• Protect the cable from heat, oil and sharp edges.
• Do not carry or fasten the device by the cable.
• Use only extension cables that are splash-proof
and intended for outdoor use. Always unroll a ca-
ble drum completely before use. Check the cable for
damage.
• Disconnect the mains plug from the socket before
carrying out any work on the device, as well as dur-
ing breaks in work and when not in use.
• Mains connection cables shall not have a smaller
cross-section than rubber hose lines with the desig-
nation H07 RN-F. The cable length must be 10 m.
The conductor core cross-section of the extension
cable must be at least 1.5 mm
Lubricants are used inside the pump which may con-
taminate the liquids flowing out of the device if the de-
vice is operated improperly or damaged.
Warning! This power tool generates an electromagnet-
ic field during operation. This field can impair active or
passive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
.
2
www.scheppach.com
6. Technical data
Product L x W x H
Mains power connection
Rated input
Max. delivery flow
Max. delivery height
Max. submersion depth
Hose connection
Max. water temperature
Protection category
Protection class
Length of mains connection
cable
Max. particle size
Weight
Subject to technical changes!
7.
Unpacking
• Open the packaging and carefully remove the prod-
uct.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the product and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
• If possible, keep the packaging until the expiry of the
warranty period. Familiarise yourself with the prod-
uct by means of the operating manual before using
for the first time.
• With accessories as well as wearing parts and re-
placement parts use only original parts. Spare parts
can be obtained from your specialist dealer.
• When ordering please provide our article number as
well as type and year of manufacture for the product.
m ATTENTION!
The product and the packaging material are not
children's toys! Do not let children play with plas-
tic bags, films or small parts! There is a danger of
choking or suffocating!
180 x 170 x 350 mm
230 V ~ 50 Hz
750 W
20000 l/h
8 m
7 m
G1 ½" = 47.8 mm
38 mm
G1" = 33.2 mm
25 mm
35°C
IPX8
I
10 m
30 mm
4.5 kg
GB | 21