NOTE: In case of obstacle detection, the Ampere-stop function halts the leaf
movement, reverses the motion for 1 sec. and stays in the STOP state.
Incorrect sensitivity setting can cause injuries to persons or animals,
or damage to things.
7.4) BUTTONS
DESCRIPTION
limit device setting and opening command. An autoset opera-
UP
tion of the torque will be performed by keeping this button
pressed for 5 seconds
DOWN
limit device setting and closing command
OK
radio programming
7.5) COURTESY LIGHT
COURTESY LIGHT
ON time starting from last
operation
Thermal overload warning
Microswitch malfunction war-
ning
8) LIMIT DEVICE SETTING (Fig.G)
1) Simultaneously press the "UP" and "DOWN" keys for 5 seconds. The "SET" led
blinks to indicate that the limit device setting is activated.
2) Bring the leaf to the required closing position, using the "UP" and "DOWN"
buttons on the control unit, and keeping in mind that the "DOWN" button
closes the leaf, while the "UP" button opens the leaf.
3) As soon as the leaf reaches the required closing position, press the "OK" button
in order to memorise the limit device closing position. The "SET" led confi rms
data storage by blinking for 1 second.
4) Bring the leaf to the required opening position, using the "UP" and "DOWN"
buttons on the control unit, and keeping in mind that the "DOWN" button
closes the leaf, while the "UP" button opens the leaf.
WARNING: in the event the track, and hence carriage travel, needs to be
shortened, cut the chain with a suitable chain link extractor.
When refi tting the cut chain, make sure that the REFERENCE CAM IS POSI-
TIONED ON THE OUTSIDE (SEE FIG. G Ref. 4a) AND THAT WHEN THE DEVICE
IS OPERATED, THE CAM ENGAGES THE MICROSWITCH LOCATED UNDER THE
BASE OF THE MOTOR.
5) As soon as the leaf reaches the required opening position, press the "OK"
button in order to memorise the limit device opening position. The "SET" led
confi rms data storage by blinking for 1 second and then lits up again.
NOTE 1: These manoeuvres are carried out in "hold-to-run" mode at reduced
speed and with no safety devices activated.
NOTE 2: In case of errors, the "SET" led remains off on for 5 seconds.
9) OPENING / CLOSING TORQUE AUTOSETTING (Fig.H)
1) After reaching the closing end-of-stroke position, press the "UP" button for 5 seconds.
2) The "SET" led blinks rapidly and the leaf starts to open until it reaches the
opening end-of-stroke.
3) 3 second down time.
4) The "SET" led blinks rapidly and the leaf starts to close until it reaches the
closing end-of-stroke.
5) After completing the autoset adjust the opening/closing torque trimmers so
as to obtain the desired sensitivity to the obstacle.
Any input activation (START, RADIO TRANSMITTER, STOP, PHOTOCELL) dur-
ing autosetting will annul the autoset in progress.
10) INTEGRATED RECEIVER
Transmitter versions which can be used:
all Rolling Code transmitters .
10.1) MANUAL TRANSMITTER PROGRAMMING (Fig.I)
1) Press the "OK" button on the control unit.
2) When the "RADIO" LED blinks, press the transmitter hidden key, and the "RADIO"
LED will stay on permanently.
3) Press the key to be memorised on the transmitter, LED "RADIO" will start
blinking again.
4) To memorise another transmitter, repeat steps 2) and 3).
5) To exit the storage mode, wait until the LED is switched off completely.
10.2) REMOTE TRANSMITTER PROGRAMMING (Fig.I)
1) Press the hidden key of a transmitter that has been already memorised in
standard mode by means of manual programming.
2) Press the normal key (T1-T2-T3-T4) of a transmitter that has been already
INSTALLATION MANUAL
DESCRIPTION
NOTES
90s
3 fl ashes at start
Allow automated device
of operation
to cool
3 fl ashes at end
Check Microswitch con-
of operation
nection
memorised in standard mode by means of manual programming.
3) The courtesy lamp blinks. Press the hidden key of a transmitter to be memo-
rised within 10s.
4) The courtesy lamp stays on permanently. Press the normal key (T1-T2-T3-T4)
of a transmitter to be memorised.
The receiver exits the programming mode within 10s., within this time new ad-
ditional transmitters can be memorised.
This mode does not require access to the control panel.
10.3) TRANSMITTER CANCELLATION (Fig.I)
To cancel the control unit memory totally, press the "OK" button on the control
unit for 10 seconds ("RADIO" LED blinking). Correct memory cancellation will be
indicated by the "RADIO" LED staying on permanently. To exit the storage mode,
wait until the LED is switched off completely.
11) AUTOMATION CHECK
Before the automation device fi nally becomes operational, scrupulously
check the following conditions:
• Check that the door (antisquash) thrust is comprised within the limits set out
by the current standards, and anyway not too strong for the installation and
operating conditions.
• Check that the spring is not pressed all the way down during operation.
• Check the manual opening control operation.
• Check the opening and closing operations using the control devices fi tted.
• Check the normal and customised operation electronic logics.
12) AUTOMATION CONTROL
The use of this control device allows the gate to be opened and closed automati-
cally. There are diff erent types of controls (manual, radio control, magnetic card
access etc.) depending on the installation requirements and characteristics. For
the various control systems, see the relevant instructions. The automation device
users must be instructed on control and operation.
13) FUSE CHANGE Fig. L
14) PULLING ARM ASSEMBLY AND ACTUATOR DIMENSIONS (FIG.P)
15) ACCESSORIES
SET/S External release device with retracting handle for sectional doors measur-
ing max 50mm (Fig.Q).
15) MAINTENANCE
Before carrying out any maintenance operation, disconnect the system power
supply.
•
Periodically check the tension of the chain/belt (twice a year).
•
Occasionally clean the photocell optical elements, if installed.
•
Have a qualifi ed technician (installer) check the correct setting of the electronic
clutch.
•
When any operational malfunction if found, and not resolved, disconnect
the system power supply and request the assistance of a qualifi ed technician
(installer). When the product is out of service, activate the manual release
device to allow the door to be opened and closed manually.
If the power supply cable is damaged, it must be replaced directly by our
company or our technical service department or by a technician having similar
qualifi cation so as to avoid any risks.
13