Components
Parallel connection with ring nut
1
2
Perpendicular connection with ring nut
3
Drain with Cap
4
Variable filtering net 300/800 um
5
Removable magnet
6
Magnet housing
7
Entry ball valve
8
Main ring nut
9
Locking spring
10
Separation ring
11
Sediments storage compartment
TECNOGAS manuale di installazione | setup manual | manuel d'instalation | manual de instalación | manual de instalare | manual de instalação
ENGLISH
Technical specifications
Maximum working pressure
Max. water temp.
Load loss
Maximum hourly flow
Internal mount
1.
Unscrew the
main ring nut
2.
4
filtering net
The
should be inside the appropriate housing, and the
should lean on the upper edge of the latter.
3.
Verify that the
drain cap
4.
Check the correct positioning of the gaskets on the
5.
Once the position of the
to screw again (without using tools) the
This procedure has already been performed on each magnetic dirt
!
separator. It is only necessary in the case of maintenance operations that
require access to the filter.
10 bar
Magnetic flow density
90 °C
Filtrarion level
0,2 bar
Magnet material
1,3 m
/h
Fittings diameter
3
8
and remove the
sediments storage compartment
3
is screwed to the end of the stroke.
connections
sediments storage compartment
main ring nut
12800 Gauss
300 - 800 um
Neodymium
3/4"
11
.
separation ring
1
2
and
.
11
is checked, it is necessary
8
.
10
11