7. Advanced functions
Switch the alarm control unit to MAINTENANCE mode (see system guide).
Open the TYDOM 2.0 unit.
To change from DHCP to a fixed IP
- Press and hold the T3 button for at least 3 seconds until the T1 LED starts flashing slowly.
- Release the button within 15 seconds
To delete the password of the TYDOM application
- Press and hold the T3 button for at least 15 seconds until the T1 LED starts flashing rapidly.
- Release the button within 30 seconds
To RESET TYDOM 2.0
(Use of DHCP, deleting the password, deleting associations, deleting current defects, restoring
factory settings)
- Press and hold the T3 button for at least 30 seconds, TYDOM emits a long beep.
- Release the button
T1
T3
40
8. Troubleshooting
This section is intended to help you quickly solve the most common problems that you
may encounter.
If in doubt, if the problem persists or if it is not in this list, please contact your installer.
The intercom quality is poor
Check that you are not using the hands-free
mode of your telephone
The voice interface does not allow you to
talk
TYDOM 2.0 must be powered
by a mains power supply.
Check the 230V power supply of TYDOM 2.0.
Move TYDOM 2.0 as far away from the antenna
as possible.
A call cycle in progress
is interrupted and replaced by another call
cycle
The technical detectors are classed in order of
priority:
1 - Smoke, fire detector
(DFR TYXAL+),
2 - Water leak detector
(DF TYXAL+),
3 - Mains power failure detector
(DCS TYXAL+),
4 - Universal detector
(DU TYXAL+).
Example: A fire alert triggered
by a DFR TYXAL+ will take priority
over the triggering of a mains failure.
The room temperature announced
by the transmitter is incorrect
Move the transmitter away from sources of heat
(ADSL box, etc.) so as not to bias the
measurement of room temperature.
A detector in the installation causes un-
timely triggering
After taking the call and listening to the
announcement, disable the relevant product.
A call cycle is not fully completed
Pressing the OFF button on a control device stops
the call cycle as soon as the ongoing
conversation is over.
The 'call numbers' and 'SIM card'
configuration menus are not available
To open these menus, your user code must be
configured as 'advanced user', contact your
installer.