6.1
Manual restart
1. After malfunctions or if no water is pumped
during commissioning, the pump has to be
started manually.
2. Check the suction side of the appliance and
the water level.
3. Start the pump by pressing the "RESET" (8)
button.
4. If no water is pumped after several unsuc-
cessful attempts, check the screw fittings for
tightness and fill the pump again.
6.2
Switching the pump off
1. Remove the mains plug from the plug socket.
6.3
Operating status displays
The operating statuses are signalled by means of
indicator lights (LED).
"Power" indicator light (5)
Indicates whether the appliance is connected to
the mains power supply.
"Failure" indicator light (6)
Indicates that a malfunction has occurred.
"On" indicator light (7)
Indicates that the pump is in operation.
Malfunction
"Power" LED does not light
up
"On" LED does not light up
"Power" LED lights up, "On"
LED is not lit
"Power" LED and "On" LED
light up
"Failure" LED lights up
12
Possible cause
No mains power.
Fault in the electronics.
Pressure line clogged.
Tapping point is higher than 15
m.
Lack of water on the suction
side.
Pump impeller is blocked.
Thermal protection device of
the pump has tripped.
Fault in the electronics.
Lack of water.
7 MAINTENANCE AND CARE
DANGER! Danger of electric shock!
There is a risk of electric shock when working on
the pump.
Disconnect the mains plug before starting
any fault remedying work.
Faults in the electrical system must be recti-
fied by a qualified electrician.
8 HELP IN CASE OF MALFUNCTION
DANGER! Danger of electric shock!
There is a risk of electric shock when working on
the pump.
Disconnect the mains plug before starting
any fault remedying work.
Faults in the electrical system must be recti-
fied by a qualified electrician.
NOTE In the event of other malfunctions,
please refer to the operating manual of the con-
nected pump. In the event of faults that you can-
not rectify, please contact our Customer Service
department.
Remedy
Check the power supply or have it
checked by a qualified electrician.
Contact Customer Service.
Check the pressure line.
Reduce the tapping height.
Check suction-side connections and
water level.
Clean the pump.
Press "RESET" button (8).
Contact Customer Service.
Check the pump and suction line
and carry out commissioning.