_ECW-012VS.book Seite 26 Montag, 15. Februar 2010 4:20 16
Connecting the inverter
Observe the following safety instructions for the electrical connections:
Caution, risk of short circuit!
e
When working on the vehicle, always disconnect the earth con-
nection to the supply battery before connecting to the starter
battery.
Disconnect the 230 V external power supply to the caravan.
If you have to feed cables through metal walls or other walls with
sharp edges, use ducts or tubes to prevent damage.
Do not lay cables which are loose or bent next to electrically
conductive material (metal).
Fasten the cables securely.
Do not pull on the cables.
Do not lay the 230 V mains cable and the 12/24 V DC cable in
the same duct.
Lay the cables so that they cannot be tripped over or damaged.
Connect the inverter as follows (see main circuit diagram in fig. 3, page 4):
Earthing the inverter
➤ Connect the earth cable (on the rear of inverter) with the earth of the ve-
hicle.
Connecting the inverter to the battery
Note
I
Please observe that all volatile memories of the connected electric
consumers will lose their stored data if the battery is disconnected.
➤ Disconnect the negative connection cable (earth) (2) from the supply
battery.
➤ Disconnect the positive connection cable (3) from the supply battery.
➤ Connect both the positive terminal on the inverter (4) and the positive con-
nection cable on the battery (3) with the two red cables (5) which are in
the included in DC kit in the scope of delivery.
➤ Connect both the negative terminal on the inverter (6) and the negative
connection cable on the battery (2) with the two black cables (7) which are
in the included in the DC kit in the scope of delivery.
26