Fault
The appliance is
unusually loud
Error code EE4
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
Power Current
CX575
220-240V~
375W
CX573
50Hz
Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load
limit) when filling.
Impact of temperature settings on food waste:
In order to reduce food waste from decomposition or dehydration, this appliance should be operated in
its designated operating range.
Optimum temperature for food storage: 6°C
To order spare parts please contact your Polar Stockist:
https://www.polar-refrigerator.com/stockist
Minimum period of spares parts to be available:
Door handles, door hinges, knobs, dials and buttons, door gaskets, peripheral trays, baskets and racks
for storage, as appropriate to the appliance, will be made available to both end users and professional
users for a minimum of eight years after the last unit of the model is placed on the market. A broader
selection of parts will also be made available to Professional users for this period.
Model information can be found on the product database:
https://eprel.ec.europa.eu/screen/product/refrigeratingappliancesdirectsalesfunction
Model information can be found on the product:
The Model Identifier can usually be found on the inside wall and on the reverse of the unit.
Note: Polar offers a 2 year minimum warranty, please contact the authorised representative for more
details.
6
CX573_CX575_ML_A5_v1_20231206.indb 6
CX573_CX575_ML_A5_v1_20231206.indb 6
Probable Cause
Loose nut/screw
The appliance has not been
installed in a level or stable
position
Restricted Airflow
Blocked Condenser
Temperature
Range
2.3A
2°C ~ 12°C
Solution
Check and tighten all nuts and screws
Check installation position and change if
necessary
Increase airflow
Clean the Condenser
Capacity
Dimensions
Refrigerant
(Ltr)
H x W x D mm
235
R290 90g
1690 x 515 x 485
Weight
(kg)
79