MAINTENANCE & CARE
12
12E
12D
12C
12 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (12A). Turn Valves
(12B) on and allow both hot and cold water to run for at least one minute each.
While water is running, check for leaks. To clean the aerator, disassemble
Aerator Housing (12A) by separating the Aerator Shell (12C), Basket (12D),
and Washer (12E). Once parts have been cleaned, reassemble by reversing
steps.
13
13B
13 HANDLE REMOVAL
Be sure Valves and Levers are in the "OFF" position. Remove handles
by holding the Lever (13A) in place and loosen the Hubs (13B) by rotating
them in a counterclockwise direction. To attach handles, rotate Hubs (13B) in
a clockwise direction.
12A
12B
13A
13B
ENGLISH
14
14 VALVE CARTRIDGE MAINTENANCE
Turn off water supplies and relieve pressure before working on your
faucet. Remove handles (See Step 13), unscrew Retainer Nut (14A) by turning
it counter-clockwise and lift out Cartridge Assembly (14B) and inspect. Replace
parts as necessary. Reassemble parts by reversing steps.
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price
Pfister Consumer Service.
Always turn off water and relieve pressure before working on your
3.
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
4
14A