Electrical supply
Before installing the oven have a qualified electrician verify
that your home is provided with adequate electrical service
and that the addition of the oven will not overload the branch
circuit on which it is to be installed.
A separate three-wire or four-wire single phase,
240 Volt, 60 Hz, or a 208 Volt, 60Hz branch circuit is
required.
NOTE: FOR USE WITH 208 V, 60 HZ SUPPLY VOLTAGE, SEE
CONNECTING TO 208 VOLT CIRCUIT.
For hook-up of the oven you will need to have an approved
junction box installed where it will be easily reached through
the front of the cabinet where the oven will be located. The
oven has 3 feet of conduit.
Allow two to three feet of slack in the line so that the oven can
be moved if servicing is ever necessary.
DO NOT shorten the flexible conduit.
LOCATION OF RATING PLATE
Wiring requirements
When making the wire connections, use the entire length of the
conduit provided (3 feet). The conduit must not be cut.
Before making connections make sure the power is off and
read and observe the following:
1. A separate three-wire or four-wire, single phase, 240 Volt,
60 Hz or 208 Volt, 60 Hz branch circuit is required for the
oven.
2. The oven must be connected with Copper or Aluminum
wire.
3. In the United States:
Wiring must conform to the National Electrical Code,
ANSI/NFPA No. 70 latest edition. You can obtain a copy
of the National Electrical Code by writing to:
National Fire Protection Association Batterymarch Park
Quincy, MA 02269
In Canada:
Wiring must conform to Canadian Electrical Code C22.1-
latest edition. You can obtain a copy of the Canadian
Electrical Code by writing to:
6
Canadian Standards Association 178 Rexdale Boulevard
Rexdale (Toronto), Ontario, Canada M9W 1R3
4. Wire size (Copper or Aluminum wire) and connections must
be suitable for the rating of the appliance as per the National
Electrical Code requirements. The flexible armoured cable
extending from the oven should be connected directly to the
junction box.
5. The junction box should be located so as to allow as much
slack as possible between the junction box and the oven so
it can be moved if servicing is ever required.
6. A U.L. listed conduit connector must be provided at each
end of the power supply cable.
Connecting to 208 volt circuit
This option is provided for areas where standard 240 Volt
service is not available. This option must be accessed with
the oven connected to power source, and using the following
sequence:
1.Within five minutes from power up, hold
keys for 3 seconds to enter the user option menu. The
display shows as follows:
2. Hold then
TIME
and
LIGHT
dark.
3. Hold
and
further, until the time display shows
MENU
LIGHT
"Volt" and temperature module shows "240" blinking,
waiting for an input.
+
-
4. Using
or
keys, the control toggles between 240V
and 208V options. Hold "OPTIONS" to confirm.
5. Hold
and
keys in order to quit the selection.
TIME
LIGHT
6. Hold
MENU
key for 3 seconds to quit the user option menu.
The voltage setting is stored and kept even after a long
power-off.
and
MENU
TIME
keys until the display becomes