FILTER ALARM
The red LED (5) will light up periodically to remind you to clean the airflow filter
at the bottom of the appliance (see section 3.2).
EN
SENSOR ALARM
The same red LED (5) will blink in the event of a sensor fault. If so, further action
is required: contact your installer or dealer (see section 4).
LIGHTS OFF MODE
For your convenience, particularly where the appliance is installed in a bedroom,
all LED warning lights will go out automatically after 10 minutes with no
intervention required on your part.
This mode affects the LEDs only and has no impact on radiator or fan operation.
Press any button to exit this mode and restore normal LED functioning.
12
3
4
5
40005954
AUTOMATIC HEAT/REFRESH MODE SELECTION
A sensor inside your radiator monitors the temperature of the hot/cold water
supply. Another sensor measures the ambient temperature in your room.
Heat Mode is selected automatically if the water temperature rises above the
minimum Heat Mode temperature: 25° C
Refresh Mode is selected automatically if the water temperature drops below the
maximum Refresh Mode temperature: 21° C
NOTE no action by the user is required to switch between these 2 modes:
NO FAN OPERATION
REFRESH MODE
21° C
NOTE in all cases, a minimum gap of 2° C between water temperature inside your
appliance and ambient temperature in your room is required for fan operation.
FAN OPERATION LOGIC
See Appendix
40005954
HEAT MODE
25° C
Water temperature inside the radiator
13
EN

Publicidad

loading