Ocultar thumbs Ver también para F1500-UPS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46

Operating Modes

Normal Operation (Utility Power) Mode
When connected to a live power source, the F1500-UPS E provides power and is
ready to provide protection from under and over-voltages. Rotate the navigation
dial to scroll through the screens.
SETUP
Automatic Voltage Regulation (AVR) Mode
Your F1500-UPS E has an Automatic Voltage Regulation (AVR) feature that will
automatically adjust the output voltage to compensate for changes in the input
voltage. There are two AVR modes; Standard - which attempts to regulate the
output voltage to within +/- 14%, and Sensitive, which attempts to regulate
the output voltage to within +/- 7%. There are limits to the range of incoming
voltage that can be regulated by the AVR circuit. The upper and lower limits are
referred to as the "capture range". If the line voltage falls outside of the capture
range, the UPS will automatically disconnect from mains power and switch over
to battery back-up mode. The specification table in the back of this manual
shows the capture range as a function of the normal voltage and AVR setting.
UPS Mode
In the event of a loss of power to the unit, over-voltage, or under-voltage, the
F1500-UPS E will function as a battery back-up. An audible alarm will sound and
the display will indicate the fault (lost power, over-voltage, under-voltage) as well
as the number of minutes of battery life remaining.
Setup Mode
The setup menu allows the user to adjust several of the operating parameters
of the unit. Please refer to diagrams on page 7 for a detailed map of the menu
structure.
Setup Menu Navigation
Clockwise (CW) rotation of the navigation dial advances the menu to the next
item. If the menu is at the last item, SYSTEM INFO, the menu will return to Normal
Operation Mode. Counter clockwise (CCW) rotation of the navigation dial sends
the menu to the previous item. If the menu is at the first item, DISPLAY BRIGHT-
NESS, the menu will return to Normal Operation Mode. Pressing the navigation
dial selects the current menu item. If there is no activity of the navigation dial
for 60 seconds, the menu will automatically return to Normal Operation Mode.
Parameter Selection and Adjustment
CW rotation of the navigation dial INCREASES the selected parameter, or advanc-
es to the NEXT available value. CCW rotation of the navigation dial DECREASES
the selected parameter, or goes back to the PREVIOUS value. Pressing the navi-
gation dial selects the current parameter value. If there is no activity on the navi-
gation dial for 60 seconds, the menu will return to Normal Operation Mode. If the
BACK parameter is selected, the menu will return to the menu item selection.
Display / Brightness
Display Brightness adjusts the brightness of the display backlight.
Display / Scroll Mode
If enabled, the display will automatically advance to the next screen
after the designated after the designated interval {5 SEC, 10 SEC}.
Normal Operation Screen
230 VOLTS
UTILITY POWER
UPS Mode Screen
LOST POWER
EST'D BATTERY: 15 MIN
Display / Sleep Mode
With Display Sleep Mode enabled, the display will go to the lowest brightness
setting (25%) after the designated time of inactivity of the Navigation Dial {30
SEC, 60 SEC }. The display will return to the set brightness level upon entering
Setup Mode, or UPS Mode.
Normal Input Voltage / Setup
Adjusts the UPS to the desired voltage {220, 230, or 240 VAC}.
Automatic Regulation Setup
Setup for Automatic Voltage Regulation parameters {STANDARD, SENSITIVE}.
Voltage Sensitivity
Adjusts the Voltage Sensitivity mode {HIGH, LOW}.
Non Critical Outlet Bank 3 Setup
Adjusts the battery charge threshold at which Outlet Bank 3 is shut off to con-
serve power for the critical loads connected to Outlet Banks 1 & 2. If set to
OFF, Outlet Bank 3 will shut off immediately when the unit goes into UPS Mode.
Adjustment range starts at OFF and runs from 90% down to 20% in 10% incre-
ments.
Non Critical Outlet Bank 4 Setup
Adjusts the battery charge threshold in which Outlet Bank 4 is shut off to con-
serve power for the critical loads connected to Outlet Banks 1 & 2. If set to
OFF, Outlet Bank 4 will shut off immediately when the unit goes into UPS mode.
Adjustment range starts at OFF and runs from 90% down to 20% in 10% incre-
ments.
External Battery
If using the external battery, BAT1500-EXT, set to YES.
IR1 Control Setup
IR1 Control Setup is a two-step process in which the IR1 remote control signal
is sampled, and tested by outputting the learned signal on the output jack (See
advanced operation section for set-up details).
IR2 Control Setup
IR2 Control Setup is a two-step process in which the IR2 remote control signal
is sampled, and tested by outputting the learned signal on the output jack (See
advanced operation section for set-up details).
IR Output Delay
IR Output Delay is the time delay before outputting the IR signals from the IR
output jacks after the unit goes into UPS mode.
IR Output Delay time starts at 0 sec, incremented in 5 sec intervals, with a
maximum value of 60 sec.
Setup Buzzer Mode
Change the UPS BUZZER MODE to set it to on or off.
UPS Test Mode
UPS Test Mode places the unit in UPS Mode temporarily to verify that the UPS
battery and inverter can adequately supply the connected load.
System Info
Displays Furman F1500-UPS E, firmware revision, and IP address
(with optional BlueBOLT CV-1 card installed).
5

Publicidad

Tabla de contenido
loading

Tabla de contenido