BLADE ASSEMBLY AND INSTALLATION
1. Mount the fan blades using the blade screws and washers provided. See Fig. 6. Make
sure all blade screws are securely fastened.
2. Fasten blade assembly to the motor using the motor screws provided. Make sure all
screws are tightly fastened. See Fig. 7.
ELECTRICAL CONNECTIONS
Connect the wires from the power supply and the bracket to the wiring terminals as
follows:
Brown L Motor: Cable
Cable black L: Light
Neutral N Blue: wire
Green / yellow: ground wire.
MAINTENANCE
HOW TO REPLACE A LIGHT BULB
1. Switch the device off (preferably, turn it off at the circuit breaker) and leave to cool.
(Take care: light bulbs can get very hot when in use.)
2. Remove the bulb by holding it firmly and turning it anti-clockwise.
3. Take a new bulb and put it carefully into its holder. Screw it in clockwise.
4. Put the power supply on again and switch on.
Important: The bulbs for this fan must be E 27 / 40 W maximum
CLEANING
Clean with a soft, dry cloth. Never use scouring pads, abrasive or chemical cleaners. Do
not
allow condensation to come in contact with the electrical components.
Disposal of old electrical appliances
The European directive 2002/96/EC on Waste Electrical and Electronic Equipment
(WEEE), requires that old household electrical appliances must not be disposed of
in the normal unsorted municipal waste stream. Old appliances must be collected
separately in order to optimize the recovery and recycling of the materials they
contain, and reduce the impact on human health and the environment. The crossed
out "wheeled bin" symbol on the product reminds you of your obligation, that
when you dispose of the appliance, it must be separately collected. Consumers should contact
their local authority or retailer for information concerning the correct disposal of their old
appliance.
DECLARATION OF CONFORMITY:
This device complies with the requirements of the Low Voltage Directive 2006/95/EC
and the requirements of the EMC directive 2004/108/EC.
 