S2S
# Entrada de pulso del medidor eléctrico 1
S3S
# Entrada de pulso del medidor eléctrico 2
S4S
# Entrada de alimentación de red inteligente
S6S~S9S
* Entradas digitales de limitación energética
S10S-S11S
# Contacto de red inteligente de baja tensión
SS1 (A4P)
* Interruptor selector
TR1
Transformador de suministro eléctrico
X6M
# Regleta de conexiones de suministro
eléctrico de la resistencia de reserva
X10M
* Regleta de conexiones de suministro
eléctrico de red inteligente
X*, X*A, J*, X*H*,
Conector
X*Y
X*M
Regleta de conexiones
* Opcional
# Suministro independiente
Traducción de texto de diagrama de cableado
Inglés
(1) Main power connection
For HP tariff
Indoor unit supplied from outdoor Unidad interior alimentada desde
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
(3) User interface
Only for ***
Only for remote user interface
SD card
WLAN cartridge
(5) Ext. thermistor
SWB
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC Control Device
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
Traducción
(1) Conexión de alimentación
principal
Para suministro eléctrico de flujo
de kWh preferente
el exterior
Suministro eléctrico de flujo de
kWh normal
Solo para suministro eléctrico
normal (estándar)
Solo para suministro eléctrico de
flujo de kWh preferente (exterior)
Unidad exterior
Contacto de suministro eléctrico
de flujo de kWh preferente:
detección de 16 V CC (tensión
suministrada por PCB)
Caja de interruptores
Use un suministro eléctrico de
flujo de kWh normal para la
unidad interior
(2) Suministro eléctrico de la
resistencia de reserva
(3) Interfaz de usuario
Solo para ***
Solo para la interfaz de usuario
utilizada como función de
termostato ambiente
Ranura de tarjeta para cartucho
WLAN
Cartucho WLAN
(5) Termistor externo
Caja de interruptores
(6) Opciones de suministro
independiente
Detección de pulsos CC 12 V
(tensión suministrada por la
PCB)
Dispositivo de control de
230 V CA
230 V AC supplied by PCB
Bizone mixing kit
Continuous
DHW pump output
DHW pump
Electrical meters
For HV smartgrid
For LV smartgrid
For safety thermostat
For safety thermostat
For smartgrid
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
Smartgrid contacts
Smartgrid PV power pulse meter Medidor de impulsos de energía
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: external heat source
output, solar pump connection,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Refer to operation manual
Solar input
Solar pump connection
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
10 Datos técnicos
230 V CA suministrados por PCB
Kit de mezcla bizona
Corriente continua
Salida de bomba de agua
caliente sanitaria
Bomba de agua caliente sanitaria
Medidores eléctricos
Para red inteligente de alta
tensión
Para red inteligente de baja
tensión
Para termostato de seguridad
Para termostato de seguridad
Para red inteligente
Corriente de irrupción
Carga máxima
Normalmente cerrado
Normalmente abierto
Contacto de termostato de
seguridad: detección de 16 V CC
(tensión suministrada por PCB)
Válvula de aislamiento
Contactos de red inteligente
fotovoltaica de red inteligente
Caja de interruptores
(7) PCB de opciones
Salida de alarma
Conmutación a fuente de calor
externa
Carga máxima
Carga mínima
Solo para la opción de PCB de
demanda
Solo para opción PCB E/S digital
Opciones: salida de fuente de
calor externa, conexión de
bomba solar, salida de alarma
Opciones: salida de
ENCENDIDO/APAGADO
Entradas digitales de limitación
energética: detección 12 V CC /
12 mA (tensión suministrada por
PCB)
Consulte el manual de
funcionamiento
Entrada solar
Conexión a bomba solar
Salida de ENCENDIDO/
APAGADO de la calefacción/
refrigeración de habitaciones
Caja de interruptores
(8) Termostatos de
ENCENDIDO/APAGADO externo
y convector de la bomba de calor
Zona de temperatura del agua de
impulsión adicional
Manual de instalación