Relay
Technical data
Device type designation
Degree of protection
Protection class
Device protection
Ambient temperature
Housing dimensions (W × H × D)
Weight
Radio frequency band
Radio protocol
Max. transmitting power
Radio range in the open
Software class / receiver category
Supply voltage
Power consumption in sleep mode
Cable type and cross section
Max. switching power:
Relay contact voltage 230 V
Relay contact voltage DC
Resistive loads
Inductive/capacitive loads
Technical modifications reserved
Symbol description
Motors
LED
Electronic transformer for low-voltage incandescent bulbs
Fluorescent lamps
Ferrite core transformer for low-voltage incandescent bulbs
Incandescent bulbs
↑Contents
8-750-002-900 | V001 | 06/2024
/ 50 Hz
AC
BMCT-RZ
IP20
II
Thermal cutoff
– 25 °C ... + 50 °C
40.5 × 47 × 22 mm
40 g
2.4 – 2.4835 GHz
ZigBee 3.0
10 dBm
< 70 m
A / 2
230 V
/50 Hz
AC
< 1 W
Rigid and flexible cable, 0.75 – 2.5 mm²
4 A, cos ϕ 0.85~1
1.7 A / 400 VA
13 A / 2,990 W
3 – 24 V / max. 8 A
The inrush current of these load types must not
exceed the value already specified for resistive
loads.
English | 13