Performance Data - Trio 596.73502201 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

H[TER
[NA
SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL 9005
Specifications
Service Flow Rate (maximum) ...............................................0.75 GPM (2.83 L/min)
Rated Service Life M odei 9005 (maximum) ...........................500 gallons/1892 liters
Maximum Operating Temperature..........................................100° F/38° C
Minimum Operating Temperature...........................................33° F/1_ C
Minimum Pressure Requirement............................................35 psi/138 kPa
Maximum Operating Pressure ...............................................120 psi/827 kPa
PERFORMANCE DATA
Substance
Lead
Lead
Cyst
Turbidity
Undane
Atrazine
Chlorine
Particulate *'
2,4-D
Asbestos
Influent Challenge
Concentration
015 mg/L +/- 10%
015 mg/L +/- 10%
Minimum 50,000/L
I1+/-1 NTU
0002 mg/L +/- 10%
0.009 mg/L +/- 10%
20 mg/L +/- t0%
at least 10,000
particles/mL
0.210 mg/L +/- 10%
107 to108 fibers/Lfibers 9ieater
than10micrometers inlength
Effluent
Average %
Maximum
Average
Reduction
Effluent
0001 mg/L
99.33%
0001 mg/L
0002 mg/L
98.66%
0003 mg/L
t count/mL
99.99%
3 count/mL
0.12 NTU
98.98%
0t8 NTU
000005 mg/L
9762%
0.00005 mg/L
00002 mg/L
9793%
0.0006 mg/L
009 mg/L
95.26%
0.17 mg/L
900 count/mL
9968%
2400 count/mL
4545 ug/L
84.42%
100ug/L
0.16 MFUmL
99.96",,, 0t6 MFUmL
Min. Required
Reduction
0010 mg/L
0010 mg/L
> 9995%
0.5 NTU
000002 mg/L
0003 mg/L
_>75%
_>85%
00017 mg/L
99%
* Tested using a flow rate of 0.75 GPM (283 L/rain ) and a maximum pressure of !20 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Ctaim
Performance tested and certified by NSF International
** Particle size range classification of test Particles used were 05 -1 microns
State of Ca[_f_111_
D_-p_ tmen_of Hea[_ S_4c_
WaI¢']
TlCalmellt
Device
Cellificate
Numbel
01
1486
Inlet
pH
6.5
8.5
NA
NA
NA
NA
NA
NA
NA
NA
GENERAL USE
CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this
refrigerator with your actual water
treatment needs.
DO NOT use this product where water
is microbiologically
unsafe or of
unknown quality without adequate
disinfection installed before or after
filtration system. Systems certified
for cyst reduction may be used on
disinfected water that may contain
filterable cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The retractable water filtration system
uses a 9005 replacement cartridge (see
Sears contact information at the back of
your Use and Care Guide to order).
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer
to the applicable section in this Use and
Care Guide for general operation,
maintenance requirements and
troubleshooting.
This system has been tested according
to ANSI/NSF 42 and 53 for reduction of
the substances listed below. The
concentration of the indicated
substances in water entering the system
was reduced to a concentration less than
or equal to the permissible limit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-KNI300 and WF50-KWlS00 tot the reduction or:
Standard No. 42: Aesthetic Effects
Standard No. 53: Health Effects
Taste and Odor Reduction
Chemical Reduction Unit
CNodne Reduction
Lead. Atrazine Lindane and 2. 4-D Reduction
Particulate Reduction Class t
Cyst, Turbidity and Asbestos Reduction
Mechanical Filtration Unit
Mechanical Filiration Unit
@
PentaPure
1000 Apollo Road
Eagan,
Minnesota
U.S.A.
EPA EST #35917-MN-1
14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

596.73503201596.73504201596.73509201

Tabla de contenido