Flangemount 4" Blower — Model 35400-Series
FEATURES
• Tough Reinforced Plastic Housing
• Mounts To Any Flat Surface
• Slip-On Inlet Ducting Connection
• Efficient High Volume Air Flow
• Low-Current Draw
• Corrosion-Resistant Materials Throughout
• N.M.M.A. Type Accepted
• Meets USCG Regulations 183.410 and ISO 8846 MARINE for
ignition protection.
• Complies with ISO 9097 MARINE VARIATIONS
SPECIFICATIONS
Model
35400-0000
35400-0010
INSTALLATION
INSTALLATIONS MUST MEET APPLICABLE
SECTIONS OF TITLE 33, PART 183; SUBPART K,
USCG VENTILATION REGULATIONS.
MOUNTING: Mount blower on flat bulkhead surface in
highest part of compartment free from spray or deck wash. Cut
dimension "B" hole in bulkhead and secure blower with washers
and No. 10 screws (NOTICE: Tighten screws evenly to avoid flange
damage). Use a suitable discharge fitting so that static pressure
of blower will not be affected by change in wind direction. Route
inlet ducting with as few bends as possible to lower 1/3 of the
bilge compartment where vapors are likely to accumulate. Be sure
ducting is positioned below top of engine stringers but not so
low as to become submerged in bilge water. Locate pickup to take
advantage of natural air flow direction.
NOTICE: Blowers should be mounted away from extreme heat
(more than 130°F (55ºC)) to prevent distortion of blower wheel
or housing.
OPERATION
See following warning placard statement:
WARNING: Explosion hazard
If pump is operated in an area containing
flammable vapors, motor wire leads must
be joined by insulated mechanical locking connectors. Loose
or inadequate wire connections can spark
resulting in an explosion. Property damage, injury or death
Air Flow
Voltage
250 CFM
(7.0 m³/min)
250 CFM
(7.0 m³/min)
can occur.
Amps
12 Vdc
12
24 Vdc
5.3
THE "WARNING" PLACARD SUPPLIED WITH BLOWER MUST BE
MOUNTED ADJACENT TO ENGINE IGNITION SWITCHES (ALL LOCA-
TIONS) TO COMPLY WITH TITLE 33, PART 183; SUBPART K, USCG
VENTILATION REGULATIONS.
Jabsco blowers are primarily intended for intermittent duty cycles
such as evacuating fuel vapors from bilge areas. If desired, they
also may be used for other general air circulation applications
with longer duty cycles. However, when doing so, it should be
noted that the maximum motor life is approximately 1000 hours.
Therefore, the blower should only be used for applications if this
length of service is acceptable.
For continuous duty applications Jabsco offers 35760 Series
Blowers. Ask your Jabsco dealer for information.
2
Fuse Size
15A
7.5A
INSTALLATION DRAWING
Inlet ducting
Weight lb (kg)
6 (2.7 kg)
6 (2.7 kg)
Vent cover
Hull