Descargar Imprimir esta página

Adler europe AD 7863 Manual De Uso página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
- Green color means medium humidity in range 51% - 69% relative humidity
- Red color means high humidity over 70% relative humidity
Please note, the relative humidity value has got 3% tolerance when illuminates up the corresponding indication light.
5.Press mode button (E) in cycle to choose desired operation mode between:
- Dry clothes mode – press the mode button (E) once, the indicator (F) will be lighted up. To get fast function fulfilling, the compressor
is working continuous without stop, except the case the water tank (3) is full. The fan keeps in high speed all the time.
- Normal operation mode – press the mode button (E) again, the indicator (G) will be lighted up. Under normal operation, compressor
work. User can set target humidity level by pressing plus and minus buttons (3). Set humidity range is: 30%-80% with 5% step. When
target humidity reaches, the compressor stop working. The fan can be set on both: high and low speed according to your need. To
choice the fan speed between low and high, press the button (D), corresponding indicator (K) for high speed and (L) for low speed
will be lighted up.
- Air circulation mode – press the mode button (E) again, the indicator (H) will be lighted up. In this mode the compressor is not
working, there is fan operation only. You can adjust the speed of fan between: low and high speed to your needs.
- Automatic mode –– press the mode button (E) again, the indicator (I) will be lighted up. Under this mode, the default target humidity
is 55%. When room humidity reaches 55%, the compressor stop working, fan keeps working only. When the room humidity is higher
than 55%, the compressor start to work again.
In the case of the electricity cut the device has memory function and it can remember the last set up.
Continuous drainage function
1. If you need to dehumidify the air for a long time, you can use the continuous drainage function.
2.Prior to continuous operation for a long duration, periodical checking is required especially for the air clean filter, the drain pipe, or
the like.
3. Take away the water tank (3) from original position, insert the attached the pipe on the hole for continuous water drain (13)
shown on picture 5.
4.When you set target humidity under normal dehumidification mode, you can set: 30-35-40-45-50-55-60-65-70-75-80%-CO-30%
and so on. "CO" means continuous dehumidifying mode. In this mode the fan speed can be chose between low speed or high speed.
5. After ending the continuous dehumidifying, disassemble the pipe, position the water tank (3) in its original place and switch off the
device.
Drain hose: length: 30 cm, internal diameter: 17 mm, external diameter: 19 mm.
Timer operation - Delay Stop function
To setting the Timer OFF function - DELAY STOP use the timer button (C).
The timer off function can be set when the device operates. Press the Timer button (C), the timer indication (M) will lighted up. The
LED digital display (S) lights up and "00" appears, you should press the plus or minus buttons (B) to select the desired time for the
device to switch off. After the timer is set, the time will be displayed for 5 seconds and remember. Once timer is set, to check with left
time press the timer button (C). The device will switch off automatically after set up time pass. To reset the timer function is need to
continuous pressing the timer button (C) while time value is flashing, the time value will be changed to zero. The timer range is from
1 to 24 hours with a 1-hour interval.
Room temperature checking
In order to check with present room temperature, press the Plus button for few seconds, when the value will be displayed on LED
digital display (S), at same time the temperature indicator (N) will be displayed.
Room humidity checking
In order to check with present room humidity, look at value shown by LED digital display (S) or look at value shown by the front digital
display (12), at same time the humidity indicator (O) will be lighted up on the control panel (1). When the present room humidity
reached the set relative humidity the target humidity indicator (P) will be lighted up.
Press the power switch (A) again to turn off the device, the device stops running, just the power indicator (R) will flashing to inform
the device is under standby status. When the device is turned on. The power indicator (R) glows.
Emptying the water tank
1. If the water tank (3) is full or the water tank (3) isn't installed in correct position, the full water tank indication (Q) lights up at control
panel (1), the buzzer sounds. The device will stop operation automatically.
2. When the full water tank indicator light (Q) is flashing, the device stops operation until the water tank is empty or set in the correct
position.
3. To remove the water tank (3) please do draw the water tank gently toward you by holding the concave parts of the water tank.
Look at picture 3.
4. To empty the water tank (3), use a handle to carry it, then tilt it as shown at picture 4 and drain the water slowly. Then, you should
7