Problem
If the battery was charged properly
The equipment does
not turn on
pump nozzles, rod, trigger or hoses
Battery charge does
not last long enough
Equipment turns on
with the red button but
does not regulate
pressure in the button
Equipment pressure
drops after some time
in operation
Leak
MAINTENANCE
What to check
If the fuse is intact
If the red switch and pump
pressure regulator are working
There are no obstructions in the
Battery charging cables
If you are trying to adjust the
pressure with the red button on
Pump fluid filter (located at
the bottom of the tank)
Spraying nozzle
Battery charge
Electric pump
Identify the leak location
Possible causes
Battery discharged
Blown fuse due to overload
Damaged switch(es)
Clogged nozzles or tubing from
the electric pump
Insufficient charging time
Damaged battery charger
The pressure regulator only works
if the red button is turned off
Saturated, damaged or poorly
installed filter
Clogged nozzle
Battery not charged for enough time
Leaking gaskets or hoses
Defective engine or engine parts
Damaged or leaky rod
Damaged or leaking trigger
Under the tank
On the tank caps
Solution
Charge battery properly
Check reasons for overload,
bare wires. Replace the fuse
only after complete inspection
Replace
Cleaning or replacing parts
Charge the battery for enough time
Replace the charger
Replace the regulator if it is not
working with the red button off
Correct the installation,
clean or replace the filter
Clean or replace the spraying nozzle
Charge battery properly
Replace or repair the electric pump
Replace
Reinstall the rod properly
Check gaskets
Replace rod
Reinstall the trigger properly
Check gaskets
Replace trigger
Correct faults in pump hose clamps
Replace the tank, if it is damaged
Only fill the tank to the limit