ELECTRICAL CONNECTION
It is necessary to have a mains power outlet of 230 V with a ground connection for the installation of the heater. The power outlet must be capable of conveying at least 450 W of power
for the lighting of the heater and must have its own breaker.
The heater is powered by means of a power cable that must be connected to the 230 V outlet. Make sure that the heater's general switch is set to 0 and then connect the power supply
cable, first behind the heater and then to the electrical outlet.
By law, the installation must have a ground connection and breaker switch. Make sure that the electrical power supply cable is laid in its final position and will not come into contact with
any hot parts.
The power outlet must be single phase with a live, neutral, and ground connection.
If the mains voltage is not sinusoidal (as with, for example, generators), the heater could show an error. The user have to install the appropriate device to achieve
a pure sine wave with a voltage between 220-230V
5. INSTRUCTIONS WHEN USING THE CONTROL PANEL
Below, an image is shown of the display that is made up of four flashing lights and two displays with four digits on each one, also including LEDs that provide information, as shown below:
If the previously indicated parameters cannot be seen on the display (such as the display does not show
the time and temperature in the usual way) or the keys do not give access to the functions mentioned in
this manual (such as for example, you cannot use the keys
manipulation of the display the setting.
THE DISPLAY CONFIGURATION IS CHANGED BY PRESSING THE SAME TIME IN THE WAY
LONG (for more than 30 seconds)
IT WILL BE CORRECTLY CONFIGURED WHEN "110" APPEARS ON THE TOP DISPLAY, AS SHOWN IN THE
IMAGE BELOW.
ADJUSTING THE POWER
This heater has five power levels at which it can operate, where 1 is the lowest power and 5 is the highest. These levels can be selected
by the user by clicking the button
As well as being able to choose between the five power levels, the heater also gives us the choice of choosing an automatic operation
mode, `A´. In this mode, the heater selects the best power level for the moment with respect to the preset temperature, modulating itself
and thus achieving a more constant temperature, faster heating, and lower fuel consumption.
Push the button
(P3) and the lower display D2 will begin to flash. With each click of this button, the power level is increased and
finally automatic mode will appear. In order to set the value desired, refrain from pressing the button
and the power value desired shall be selected.
REGULATING THE ROOM TEMPERATURE
Each user has the option to choose the desired room temperature.
When a preset temperature is chosen, the heater will compare it with the temperature detected by the room temperature sensor.
As long as the preset temperature is above the temperature measured by the room temperature sensor, the heater will run at the power
level selected. When the room temperature approaches the preset temperature, the heater changes to modulation `mod´.
If, whilst in modulation mode, the temperature detected by the room temperature sensor should rise by more than 3 °C, the heater will
turn itself off by putting itself in `standby´ mode. The heater will turn itself back on when the room temperature is beloww the desired
room temperature. To modify the preset temperature, click on the
temperature that was already chosen can be seen flasing, which can be increased or decreased by clicking on the
(P4) buttons, respectively. After five seconds without any button being pressed, the new value will be saved and the display will return
to the main screen.
AFTER CARRYING OUT THIS OPERATION, BEFORE PROCEEDING TO TURN THE HEATER ON, IT IS NECESSARY TO EMPTY THE
BURNER AND REPLACE IT CORRECTLY. IF IT IS NOT CORRECTLY REPLACED, IT COULD CAUSE DIFFICULTY WHEN TURNING
THE UNIT ON
KEY
P1
P2
P3
P4
(P2) or
(P1) AND
(P3).
(P3).
(P2) or
LOADING THE PELLET SCREW
This function allows you to fill the screw for the first time that the heater is going to be started up and also when, for whatever
reason, the fuel tank has been completely emptied.
This is done by pressing the
display shows `LoAd´, the upper display will show for how long it has been operating. Stop loading when the pellets fall
uninterrptedly into the brazier, which can be achieved by pressing any button. For safety reasons, loading is automatically
interrupted after 300 seconds.
30
30
FUNCTION
CLIC
Information/Exit Menu
Adjust thermostat (+)/ Increase
Adjust combustion power
Adjust thermostat (-)/ Decrease
(P4)), it could be that during the
(P3), it will then stop flashing
(P4) button. On the lower display (D3) the preset
(P2) or
(P3) button, with the loading screw being activated continuously. Whilst the lower
LONG PRESS
On/ Off/ Reset alarms
First screw fill