RADIOPROGRAmmER S46 WITH PROGRAmmABLE CODE
REmARkS
These instructions are aimed at professionally qualified "INSTALLERS OF
ELECTRICAL EQUIPMENT" in conformity with the local standards and
regulations in force.
This appliance must be used exclusively for the purpose for which it has been
made. Any non authorised modifications are to be considered improper and
therefore dangerous.
The manufacturer accepts no liability for damage caused by, or situations
arising from, the improper use of these appliances.
Description
The S46 radioprogramming system consists of one or more transmitter and
one or more receivers which can be combined to meet the specific needs
of the client.
The single channel radio receiver (with functions A, B, C, D) offers up to
19683 code combinations per appliance set by a block of 9 three-way dip-
switches.
Use
The radioprogrammer allows the remote activation of a single-phase motor
230V ac 350W, with dynamic functioning for the sequence open-stop-
close.
Compatibility with RXPR:
• The transmitters are fitted with a jumper "JC" to maintain compat-
ibility with receivers of the series non "C".
- Jumper inserted:
compatible with NON series "C" receivers
- Jumper not inserted:
compatible with series "C" receivers
Transmitter versions
TRQ466200
Pocket size transmitters
TRQ466400
Pocket size transmitters
Receiver versions
RPQ046
Radioprogrammer
Receiver antenna installation
Minimum and maximum range of the radio controls.
"Range" is intended to mean the working distance, measured in free space,
between the receiver and the transmitter with the antenna installed. The
range is therefore closely linked to the technical characteristics of the system
(power and sensibility) and varies according to the characteristics of the site
in which the system is located.
It therefore follows that to obtain the best results from the radio control
the installation sites for the receiver and the antenna should be carefully
chosen.
It is not possible to install 2 receivers at a distance of less than 1,5m from
each other. It is good practise to position the receiver away from computer
systems, alarm systems and other possible sources of disturbance.
(A bad choice of positioning could compromise the performance of the
receiver).
ANTENNA
The installation of the antenna is fundamental, connected to the receiver it
represents the reception point for the radio control.
When installing the antenna the following points should be observed:
- Only use a tuned antenna connected to the receiver using a coaxial cable
RG58 (impedance 50Ω) with a maximum length of 15m.
- The antenna should be positioned out of doors in the highest possible
point, visible and away from metal structures.
N.B. If for some particular reason it is not possible to fit an antenna, a rea-
sonable performance can be obtained by connecting a 2,5m piece of single
pole conductor wire (Ø1mm) to the receiver.
INSTALLATION
Depending on the type of installation, work out the position in which the
programmer will be situated remembering that the site must be:
- a position safe from accidental collision;
- high enough above the ground to be safe from pools of water;
- in a position which the technician can easily reach.
The fixing of the case type receiver is carried out by using "fast-fitting"
brackets. The bracket should be fixed to the wall using two raw plugs (check
that it is plumb to the wall), the case can then be slid onto the bracket and
fastened securely to the wall.
The slot-in circuit located towards the bottom of the case can be easily
extracted to facilitate wiring up the device.
If any repair work is necessary the case can be easily extracted by pushing
upwards the action of which will separate it from the bracket.
ELETTRONICA
spa
+39/0438.404011-401818
+39/0438.401831
Sales.office.it@cardin.it
Sales.office@cardin.it
www.cardin.it
2 channels
4 channels
SERIAL NUMBER
ZVL126.05
The S46 series conforms to the essential requirements of the directive 99/05/CE and the
technical reference standards have been applied. This product has been tried and tested
in the manufacturer's laboratory, during the installation of the product follow the supplied
indications carefully.
ELECTRICAL CONNECTION (fig. 3)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains
supply;
- a bipolar circuit breaker which leaves at least 3 mm between the contacts has been
installed between the device and the mains;
- the high voltage 230V wires pass through the holes marked "A" and are routed
separately from the low voltage wires which pass through the holes marked "B";
- the wires are fastened down using a cable clamp;
- once the wiring is complete the holes through which the wires have passed have
been sealed using silicon;
- the holes which are not used are sealed by inserting the sealing caps "D".
• Only low voltage circuits may be wired to the external circuit binding posts .
TERmINAL BOARD CONNECTIONS (fig. 3)
1-2
Earth connection
3-4
Radioprogrammer power supply 230 Vac 50-60 Hz
5-6-7 Motor control in output 350 W Close-Open-Neutral
TD Dynamic button in input (contact N.O.)
8-9
10-11 FTCII Contact N.C. in input for safety devices with travel direction inversion.
Any eventual safety devices must be powered by an external power circuit
12
Antenna braid
13
Radio receiver antenna
Settings (fig. 3)
TL
Work cycle regulation trimmer (3...120 sec.). The timer countdown starts after an
opening or closing command has been received and stops after the programmed
work time has elapsed.
PW
Power on LED.
STS Lit: work cycle in course; flashing: photoelectric cell in alarm.
TRANSmITTERS
In the transmitters each button corresponds to a different function, with the sole excep-
tion of the two button transmitters where it is possible to have the same function for
both buttons (single-channel operation). For double-channel operation which can be
obtained using the second key, set the two-way DIP-SWITCH, located separately from
the nine-way user code DIP-SWITCH on the printed circuit board. Once the transmitter's
functions have been programmed and recognized, make sure that the jumper position
in the radioprogrammer corresponds to the desired function.
PROGRAmmING THE USER CODE
The transmitters and receivers are supplied with a block of DIP-SWITCHES +0- with
which to program the digital codes for each system. Programming can be carried out
more than once, even after the installation, thus ensuring the total secrecy of the user
code. To ensure an exact match between the transmitter and receiver codes, when
programming the various functions must be taken into account.
Functions
The desired functions in the receiver are selected by setting the jumper situated on
the circuit board. The functions are printed on the circuit board in silk-screen form
A, B, C, D.

TECHNICAL SPECIFICATIONS

RECEPTION FREQUENCY
Attention: The transmission frequency of these products varies according
to the approved frequency and eventual personalisation in the country of
destination
Country
Frequency
Italy
29,875 MHz
Europe
27,195 MHz
USA
27,195 MHz
RECEIVER
- local oscillation frequency tolerance .............................................30p.p.m. (-10°... +55°)
- intermediate frequency ........................................................................................455 kHz
- impedance in input .................................................................................................... 50Ω
- sensibility .................................................................................................................0.5µV
- local oscillation emission .................................................................. <-70dBm (<100pW)
- power supply ........................................................................................ 230 Vac 50-60Hz
- operating temperature range ........................................................................-20°...+60°C
TRANSmITTERS
- carrier frequency tolerance .................................................30p.p.m. from -10° to +55°C
- band width ............................................................................................... 10 kHz/ ± 5kHz
- apparent radiated power ........................................................ -10...-7dBm (100-200µW)
- apparent power harmonic products ..................................................... <-64dBm (<1nW)
- power output adjacent channel (± 10 kHz) ........................................ <-37dBm (<0.2µW)
- modulation .......................................................................................................... AM/ASK
- signal modulation.....................................................................................PCM, 1.3ms/bit
- power supply ..................................................................................................12V ± 10%
- maximum power consumption ............................................................................. <38mA
- operating temperature range .......................................................................- 20... +70°C
- relative humidity ...................................................................................................... <95%
SERIES
MODEL
S46
RXPR
06-07-2001
Antenna
ANQ730
ANQ727
ANQ727
DATE

Publicidad

loading

Este manual también es adecuado para:

S46 rxpr