05/03/2021
According to
the low voltage
directive:
2006/95/EC /
the EMC directive:
2004/108/EC
fuse holder
with spare
minimum speed
adjustment trimmer
net weight
gross weight
160 gr
190 gr
RM-00
ETX/ETY15
ETX/ETY15
RM-01
175 gr
200 gr
ETX/ETY25
RM-02
210 gr
235 gr
MOUNTI NG INSTRUC TIONS
EN
Speed controller for single phase voltage controllable motors
Technical data
Voltage: 230 VAC - 50 Hz
Current range Fuse
ETY/ETX-0-15-AT 0,05-0,5 A
RM-00
F 0,63 A - H
ETY/ETX-0-15-AT 0,1-1,5 A
RM-01
F 2,0 A - H
ETY/ETX-0-25-AT 0,2-2,5 A
RM-02
F 3,15 A - H
Enclosure external: plastic, ASA, RAL 9010 white-ivory
Enclosure internal: polyamide According to IEC 60335
For indoor use only, non-condensing!
Inset mounting (IP 44)
Break mains voltage. Connect according to diagram. Mount
innercase to the wall with connections pointing down. Turn
on mains voltage and controller. Adjust min. speed and turn
Surface mounting (IP 54)
Break mains voltage. Mount surface mounting case to the wall
together with included grommets. Connect according to dia-
gram. Mount inner case in surface mounting case with included
screws. Turn on mains voltage and controller. Adjust min. speed
When needed a 5 mm hole for condensation water is to be
drilled at the bottom of the surface mounting case.
Adjustment
The trimmer is adjusted so that the motor does not stop due
to variations of mains voltage and that it restarts after power
failure. ( conn. 2 ): Extra connection to, for example, damper
or use as inlet to the controller without bypassing breaker of
turning knob.
1
2
after switch (Imax: 2 A)
Input: to bypass switch
N neutral
3
regulated output to motor
4
fuse holder with spare
5
minimum speed adjustment trimmer
Type of motor
The controller is only to be used together with fans that are
suitable for speed control. The motor used should be internally
protected against overheating.
In case of faulty operation
Please check that: Right voltage is applied. All connections are
correct. The machine to be regulated is functioning. The fuse in
fusebox is OK. The fuse in the controller is OK.
Change of fuse
stop and then pull. Remove the nut. Remove fuse holder with
a screwdriver. Change fuse. Put the details back in place. Use
only recommended fuses ( Approved, fast, with high breaking
capacity ) otherwise loss of warranty will ensue.
Warranty
Two years from delivery date against defects in manufactur-
manufacturer of all responsibility.
The manufacturer bears no responsibility for any misprints or
the product can be made at any time after date of publication.
Maintenance
In normal conditions the controllers are maintenance-free. If
soiled clean with dry or dampish cloth. In case of heavy pol-
lution clean with a non-aggressive product. In these circum-
stances the controller should be disconnected from the mains.
the controller to the mains when it is completely dry.
All works may only be carried out by skilled personnel
following the local regulations and AFTER the controller
is completely separated from the mains.
Replace fuse only with same type and rating.
NL
Toerenregelaar voor éénfase spanningsregelbare motoren
Technische gegevens
Netspanning: 230 VAC - 50 Hz
Bereik
Zekering
ETY/ETX-0-15-AT 0,05-0,5 A
RM-00
F 0,63 A - H
ETY/ETX-0-15-AT 0,1-1,5 A
RM-01
F 2,0 A - H
ETY/ETX-0-25-AT 0,2-2,5 A
RM-02
F 3,15 A - H
-
Behuizing extern: plastic, ASA, RAL 9010 ivoorwit
Behuizing intern: polyamide volgens IEC 60335
Voor gebruik binnen, niet-condenserend!
Montage-aanwijzingen voor inbouw (IP 44)
Door de bedieningsknop verder dan de max. stand te draaien
kan hij gemakkelijker afgenomen worden. Eventueel een kleine
schroevendraaier gebruiken. Na verwijderen van de zeskant-
moer in het midden op de regelaar met de aansluitklemmen
aan de onderzijde, volgens onderstaand schema aansluiten.
Spanning geven en met de trimpotentiometer, het kleine zwar-
instellen. De afsluitkap monteren. De stelknop vast aandrukken
en op 'uit' instellen.
Montage-aanwijzing voor opbouw (IP 54)
Handel als beschreven onder 'inbouw' . De regelaar kan met de twee
meegeleverde schroeven in de kast worden vastgezet. De afdich-
tingsring niet gebruiken. Aan de onderzijde van de opbouwdoos
moet bij extreem vochtige omstandigheden een condenswater-
opening geboord worden (max. 5 mm ). Met twee meegeleverde
Extra aansluiting
De tweede aansluiting van links, gemerkt met blijft 230 Volt
spanning voeren. Daarop kan bijvoorbeeld een regelklep of een
signaallamp worden aangesloten.
1
2
niet-geregelde uitgang 230 VAC, of ter overbrugging van
N neutral
3
geregelde uitgang naar motor
4
ingebouwde zekering met reserve (snel, keramisch)
5
minimum speed adjustment trimmer
Instellen trimpotentiometer
zo ingesteld worden dat de motor ook bij het laagste toerental
aanloopt.