Replacing the fuse (UK plug only)
If the fuse needs replacing, please observe the following:
• Remove the mains plug.
• Lift out the fuse holder from the inside of the mains plug using a flat screwdriver.
• Pull out the fuse from the fuse holder and replace it with a new fuse type: 3A (breaking capacity 6 kA at 240
V) in accordance with BS-1362 / SS167.
• Press the fuse holder containing the new fuse into the plug slot.
• Plug the mains plug into the socket,press ON/OFF switch (3) and test to see if it works.
Changing the infrared lamp
Remember that a faulty lamp should only be replaced with a lamp of the same type.
Warning
Danger of an electric shock!
• Before changing the lamp, make sure the power cable
is unplugged from the socket.
• Risk of burning on hot surfaces!
• Allow the unit to cool completely before any repairs.
• Lamps are not covered by the guarantee.
Procedure
1. Place the cool unit with the glass ceramic plate down
on a flat surface.
2. Using a suitable crosshead screwdriver, undo the
8 screws in the back panel.
3. Place the body so that the front ofthe glass ceramic
plate is lying on the flat surface.
4. Take the cool lamp by the left or right end and press it
carefully to the right or left.
5. Now lift it forwards and out of the socket.
Note
Use a cloth to hold the new lamp when inserting it, not
bare fingers, as the grease on your skin could damage
the coating on the lamp.
6. Insert the new lamp in the socket. The new lamp is in-
serted in the reverse order to removal.
7. Close the unit again. The unit is closed in the reverse
order to opening it.
Make sure that no foreign objects are left in the body of
the unit and that nocables become trapped.
Storage
Remove the mains plug and let the unit cool down completely before you move it.
If possible, store the infrared radiant heater in its original packaging in a dry place.
18