9. Specifications
Case
Case
Case material
316L
Case options
Field case
Cable outlet
Metal cable outlet, shield optionally connected (heavy-duty version)
Suitable for the following gases
SF
6
N
2
CF
4
O
2
CO
2
Novec 4710
He
Ar
Gas mixtures and components can be individually configured and combined at the factory. The calculation is based on
the physical principle of the partial pressure method. The gas mixture cannot be changed subsequently.
Output signal
Output signal
Voltage supply
Power consumption
Model GD-20-A
Model GD-20-D
Maximum permissible load R
Time response
1)
Settling time
2)
Switch-on time
1) E.g. with any sudden pressure spikes
2) Time after switching on until the first measured value is output.
WIKA operating instructions gas density sensor, model GD-20
DC 10 ... 30 V
≤ 0.75 W
≤ 0.45 W
≤ (U
(model GD-20-A)
R
A
A
< 10 ms
≤ 500 ms
in Ohm and U
- 9.5 V) / 0.023 A with R
B
A
in V
B
63