Code
d0
IPM mould temperature
d1
Inlet water temp.
d2
Outlet water temp.
d3
Ambient temp.
d4
Frequency limitation code
d5
Piping temp.
d6
Gas exhaust temprature
d7
Step of EEV
d8
Compressor running frequency
d9
Compressor current
d10
Current fan speed
d11
Error code for last time
Remark:
d4: Frequency limitation code,
0: No frequency limit;
2: Overheating or overcooling frequency limit; 4:Drive Current frequency limit;
8:Drive voltage frequency limit;
5.2.6 Parameter setting
Press
,then press
parameter will flash.
Condition
1:Coil pipe temperature limit;
16:Drive high temperature frequency limit
to choose P0-P18 value, and press
Scope
0-120℃
-9℃~99℃
-9℃~99℃
-30℃~70℃
0,1,2,4,8,16
-30℃~70℃
0℃~C5℃ (125℃)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error code
again to enter the setting interface,in which
60
Remark
Real testing value
Real testing value
Real testing value
flash if Real value<-9
Real testing value
flash if Real value<-9
Real testing value
N*5
Real testing value
Real testing value
Real testing value