Muestra el ejemplo
(cs2) # show version
Switch: 1
System Description................... Broadcom Scorpion 56820
TENGIG,
Machine Type......................... Broadcom Scorpion 56820
Machine Model........................ BCM-56820
Serial Number........................ 10611100004
FRU Number...........................
Part Number.......................... BCM56820
Maintenance Level.................... A
Manufacturer......................... 0xbc00
Burned In MAC Address................ 00:A0:98:4B:A9:AA
Software Version..................... 1.1.0.5
Operating System..................... Linux 2.6.21.7
Network Processing Device............ BCM56820_B0
Additional Packages.................. FASTPATH QOS
2. Conecte los puertos ISL en cs1, el switch activo.
configure
Muestra el ejemplo
(cs1) # configure
(cs1) (config) # interface 0/13-0/16
(cs1) (Interface 0/13-0/16) # no shutdown
(cs1) (Interface 0/13-0/16) # exit
(cs1) (config) # exit
3. Compruebe que los ISL estén operativos:
show port-channel 3/1
El campo Estado del enlace debe indicar Up.
10
Development System - 16
1.1.0.5, Linux 2.6.21.7
Development System - 16TENGIG
FASTPATH IPv6 Management