Physical installation: light switches
Pictures explaining the steps at the end of this manual.
Before starting the installation of the switches, switch off the power supply and ensure
that there is no risk of electrocution.
1.
Identify the front and rear of the metal frame. The side with the CE RoHS logo is the rear side
which must be mounted on the wall. The metal disassembly notch must face downwards.
2.
Insert the switch into the metal frame, passing it from the front towards the rear of the
frame. The mounting direction of the electrical part is marked on the rear text. Make sure that
the 4 tabs (2 upper and 2 lower) are fastened.
3.
Make the wiring connection according to the diagrams included in this manual.
4.
Screw the assembly to the wall.
5.
Attach the front trim. To do this, first fit the upper part into the metal frame and press the
lower part (make sure that the installation direction is correct by matching the disassembly
notches).
Physical installation: 47 mm panels
The 47 mm panels are glass plates that vary according to the function of
the switch and are installed inside a frame.
1 - 4.
Follow steps 1 to 4 in the section "Physical installation: switches".
5.
Locate the mounting adhesive and remove the centre part of the
adhesive (it should be hollow).
6.
Remove the paper covering the sticker on one side and stick it onto
the back of the trim frame, matching the flaps with the space provided
for them.
7.
Attach the glass bezel to the central adhesive, matching the matt
side of the glass against the adhesive surface and respecting the
direction of the buttons. The shiny part of the glass must face outwards.
8.
Fix the front frame. To do this, follow step 5 of the section "Physical
installation: light switches".
Wiring diagrams:
N
Capacitor
Lamp
L
N
L
L1 L2 L3
N
Capacitor
Lamps
L
N
L
L1 L2 L3
Light switches
N
Capacitor
Lamps
L
N
L
L1 L2 L3
N
Motors
L
L
L1 L2
N
Roller shutter switch