Detector de presencia por infrarrojos

Publicidad

the "moon" position (min). As for the adjustment pattern, please refer to the testing pattern.
SENS adjustable: It can be adjusted according to using location. The detection distance of
low sensitivity could be only 5m and high sensitivity could be 12m which fits for large room.
Time-Delay is added continually: When it receives the second induction signals after the
first induction, it will compute time once more on the basic of the first time-delay rest.
INSTALLATION ADVICE: As the detector responds to changes in temperature, avoid the
following situations: Avoid pointing the detector towards objects with highly reflective
surfaces, such as mirrors etc. Avoid mounting the detector near heat sources, such as
heating vents, air conditioning units, light etc. Avoid pointing the detector towards objects
that may move in the wind, such as curtains, tall plants etc.
WARNING! Danger of death through electric shock! Must be installed by professional
electrician. Disconnect power source. Cover or shied any adjacent live components.
Ensure device cannot be switched on. Check power supply is disconnected.
CONNECTION: Screw off the nail on the front cover and unload the front cover. (refer to
illustration). Find the wire hole with gasket in the bottom and pass the power wire through
hole. Fix the bottom on the selected position with the inflated screw (refer to illustration).
Connect the power wire into connection-wire column according to the connection-wire
diagram. Install back the front cover, tighten the screw and switch on the power.
Then you can test it.
CONNECTION-WIRE DIAGRAM: (See the ilustration)
TEST: Turn the LUX knob clockwise on the maximum (sun). Turn the TIME knob anti-
clockwise on the minimum. Turn the SENS knob clockwise on the maximum. Switch on the
power; the load and the indicator lamp don't work. After Warm-up 30sec, the indicator lamp
turns on .Under the condition of no sense signal, the load should stop working within
10sec±3sec and the indicator lamp would turn off. After the first induction is out, make it
sense again after 5~10sec. The load should work again. When no sense signal, the load
should stop working within10sec±3sec. Turn LUX knob anti-clockwise on the minimum
(moon). If the ambient light is more than 3LUX, the inductor load should not work after the
load stop working. If you cover the detection window with the opaque objects (towel etc),
the load would work .Under no induction signal condition, the load should stop working
within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor
lamp could not work! If the lamp is more than 60W, the distance between lamp and sensor
should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
The load do not work: Please check if the connection-wiring of power and load is correct.
-2-
Please check if the load is good. Please check if the working light sets correspond to
ambient light.
The sensitivity is poor: Please check if there has any hindrance in front of the detection
window to affect to receive the signal. Please check if the ambient temperature is too high.
Please check if the induction signal source is in the detection fields. Please check if the
installation height corresponds to the height showed in the instruction. Please check if the
moving orientation is correct.
The sensor can not shut off the load automatically: Please check if there is continual signal
in the detection field. Please check if the time delay is the longest. Please check if the
power corresponds to the instruction.
PL
Ścienny czujnik ruchu
OPIS: Produkt posiada wysoką czułość i poziom wykonania. Główne cechy to automatyzm,
energooszczędność. Czujnik identyfikuje dzień i noc (możliwość oświetlenie za dnia miejsc
ocienionych). Lampa włącza się i wyłącza w zależności od pojawienia się obiektu w polu
detekcji. Urządzenie jest proste w instalacji.
PARAMETRY:
Zasilanie: 220-240V/AC
Kąt detekcji: 180°
Częstotliwość zasilania: 50Hz
Zasięg max.: 5-12m (<24°C) (regulowany)
Czułość oświetlenia: <3-2000LUX (regulowany)
Temperatura pracy: -20~+40°
FUNKCJE: Urządzenie może działać zarówno w nocy jak i w dzień. Pokrętło TIME służy do
regulacji czasu oświetlenia (od około 10 sek do 7 minut). Pokrętłem LUX ustawiamy czułości
światła otoczenia (zakres od 3 do 2000 LUX). Gdy światło otoczenia jest niewystarczające
i chcemy, aby urządzenie pracowała zarówno w dzień jak i w nocy ustawiamy pokrętło
w pozycji dzień (ikona słońca). Gdy światło otoczenia jest mniejsze niż 3 LUX, pokrętło
powinno być ustawione w pozycji noc (ikona księżyca). Pokrętło SENS służy do regulowania
maksymalnego zasięgu (od 5-12m) w zależności od miejsca w którym znajduje się czujnik.
Odległość zasięgu 12m zaleca ustawiać w bardzo dużych pomieszczeniach.
INSTALACJA - PORADY: Detektor reaguje na sygnały zmiany temperatury oraz na zmiany
położenia obiektów. Unikaj kierowania detektora w obiekty z powierzchnią odbijającą
światło (np. lustra). Unikaj montażu w pobliżu źródeł ciepła, takich jak klimatyzacja, źródła
światła, ogrzewania itp. Unikaj kierowania czujnika na obiekty poruszające się zależnie od
wiatru (zasłony, rośliny itp.) UWAGA! Zagrożenie życia poprzez porażenie prądem! Zaleca się
aby montażu dokonała osobą doświadczona w tym zakresie. Odłącz źródło prądu przed
montażem. Urządzenie nie powinno być włączone w trakcie montażu. Osłona obudowy
MCE25
Zakres czasu oświetlenia: 10sec~7min
Zakres wilgotności pracy:<93%RH
Pobór mocy: około 0.5W
Maksymalna moc: 1200W
300W
Prędkość detekcji ruchu: 0.6-1.5m/s
Wysokość instalacji: 1.8-2.5m