O 10 cm
ISPECTION
ISPECTION
O 8 cm
ISPECTION
If a "traditional" flue is used for the exhaust of the flue gas, make sure that is in good working order. If the flue should be old or too big (internal section larger
than 15x15 cm or internal diameter greater than 15 cm) duct the flue using an appropriately insulated stainless steel pipe (using rock wool or vermiculite) and
dimensioned on the basis of the route. The connection to the flue must be appropriately sealed.
When realising the flue, there must not be more than 4 direction changes, including the initial T-shaped fitting.
CONNECTIONS
Electrical connection
The electric connection must only be performed by qualified staff, with respect to all general and local Safety Standards in force.
Check that the power supply voltage and frequency correspond to 220V – 50 Hz.
Appliance safety is obtained when the same is correctly connected to an efficient earth plant.
In the electric connection to the mains power supply, envision a 6 A – Id 30 mA differential magnet circuit breaker switch with relevant breaking load. The
electric connections, including the earth, must be made after the voltage has been removed from the electric plant.
When realising the system remember that the cables must be placed in an unmovable and away from parts subject to high temperatures. During the final
wiring of the circuit, only use components with a suitable electric protection rating.
KLOVER srl declines all responsibility for injury to persons, animals or damage to objects deriving from the failure to connect the network to
earth and failure to comply with the IEC Standards.
The electronic control unit manages and controls all insert functions always assuring excellent functioning of the entire appliance.
Controlling any coupled boiler
If the insert is to be coupled with another boiler already installed in the system (e.g. wall-hung gas boiler), it must be ensured that when the insert functions
for the heating system, the boiler stops. This is so that the calories in the two appliances installed in the system do not have to be added. This is why our set-
up intervenes on the coupled boiler when the insert heating pump starts. In this way, there will never be two boilers functioning simultaneously in the same
system. The coupled boiler will always be able to be used for the production of domestic hot water.
The two wires prepared on the back of the insert (blue and brown wires), on outlet will have a voltage of 220 V when the insert pump functions, no
voltage when the pump is at a standstill.
It is therefore easy to connect the two wires to a relay that will control the Room Thermostat inlet of the coupled boiler.
10