the current pulled by most two-wire components like decoders and
sensors on the field cable. To use this function:
1. Disconnect the two-wire control cable from the controller.
2. Connect the Pro50™ test leads to the two-wire control cable
(red to red, and black to black). See image below.
3. Press F2 from the main screen. This will pull up the two-wire
fault-finding screen. See image below.
4. Press F1 ON to power the 2-wire cable. This will provide
power to the two-wire cable for 15 minutes before timing out.
Press F2 if you'd like to change the timeout from 15 minutes
to 30 minutes.
5. Press F3 OFF to stop powering the two-wire cable.
6. Press the left arrow to return to the home screen.