Ermenrich Seek DN10 Digital Anemometer
EN
The kit includes: anemometer, pouch, user manual, and warranty.
Getting started
Open the battery compartment cover (8) and insert 3 AAA batteries. Close the cover.
Press the Power button (5) to turn the device on or off.
Display information
Icons
MAX
MIN
AVG
°C
°F
%RH
x10
Wind speed measurement
To measure wind speed, hold the anemometer vertically with the wind direction of the airflow. The screen will simultaneously display
wind speed, temperature and humidity values.
Data hold
To freeze the displayed values, press the Data hold / Backlight button (6).
will be displayed. To return to normal mode, press the Data hold / Backlight button (6) again.
Backlight on/off
To turn the backlight on/off, hold the Data hold / Backlight button (6) for 2–5 seconds.
MIN/MAX/AVG function
Press the MAX/MIN button (4) to display the maximum recorded wind speed. After pressing the MAX/MIN button (4) again, the
maximum, minimum and average value of the recorded wind speed will be displayed successively on the screen. To return to normal
mode, hold the MAX/MIN button (4) for 2–5 seconds.
Selecting the units of measurement
Press the °C/°F button (3) to select temperature units. Press the UNIT button (7) to select wind speed units (m/s, km/h, mph, ft/min, ft/s,
knots).
High wind speed mode
If the wind speed is extremely high and does not fit on the screen, the x10 icon automatically appears on the screen. This icon indicates
that the actual wind speed is 10 times higher than the number displayed on the screen.
Automatic shutdown
When you turn on the anemometer, the automatic shutdown function is activated by default. If there is no activity for 10 minutes, the
device will automatically shut down.
To disable this function, press and hold the Data hold / Backlight button (6) prior to turning on the anemometer. Without releasing the
Data hold / Backlight button (6), press the power button (5). After turning on the device, release the Data hold / Backlight button (6). The
automatic shutdown function will be disabled.
To make the automatic shutdown feature work again, restart the device.
When the automatic shutdown function is working, the
not appear on the screen.
Description
Data hold
Maximum value
Minimum value
Average value
Temperature Celsius
Temperature Fahrenheit
Relative humidity
Wind speed diagram
High wind speed mode
icon is displayed on the screen. When this function is disabled, the icon will
3
Icons
m/s
km/h
mil/h
ft/m
ft/s
knots
icon will appear on the screen. Then the last recorded value
Description
meters per second
kilometers per hour
miles per hour
feet per minute
feet per second
knots
Battery status indicator
Automatic shutdown

Publicidad