32
UK
In detail with operator installed on LEFT leaf:
• The valve È 5 controls reversibility in OPENING.
[ ]
• The valve É 5 controls reversibility in CLOSING.
[ ]
In detail with operator installed on RIGHT leaf:
• The valve È 5 controls reversibility in CLOSING.
[ ]
• The valve É 5 controls reversibility in OPENING.
[ ]
15 - ELECTROLOCK INSTALLATION
[15a]
Refers to pictures
À Electrolock.
Á Electrolock fixing plate.
 Bolt hooker.
à Bolt hooking rabbet.
Ä Bolt.
Å Key cilynder (on request).
Æ Gate.
16 - LIMIT SWITCH KIT (OPTIONAL)
FLOOR operator is suited to be equipped by limit switch kit with Hall effect sensor.
The kit allows you to switch, when used with appropriate electronic control device, a better and more precise
control of leaf movement; the more benefits you get with the operator FLOOR 24Vdc.
The kit consists of:
• Hall-effect sensor À [16a] which is fastened with two screws on the operator housing Á [16a].
• A disk plate  [16a] to be fixed under the sleeve spline à [16a] with two screws Ä [16a].
• Two plastic magnets holders Å [16a], one black and one white, which are fixed on the disk plate with two
screws each Æ [16a] and on which, by loosening the screws, they will be free to slide.
Each magnet holder is pre-assembled with two magnets oriented in the same sense of polarization: the black
one is pre-assembled with two magnets that control the closing, the white one is pre-assembled with two
magnets that control the opening [16b].
The wiring diagram of the sensor is in [16c].
Using Gi.Bi.Di. control units properly set, the former magnet passing on the Hall effect sensor starts slow down
motion, the latter stops slow down motion.
Refer to the instruction manual of the electronic control unit.
[15b]
and
. The electrolock must be installed on leaves 2.0 meters long or more.
FLOOR