OPERATION
Remove the laser from its carrying case. The instrument is shipped with a battery current
protection insert, which must be removed before operation.
NOTE: All KL850 and KL850V instruments are shipped with ADS on as the default setting. This
setting can be changed by the user (see Anti-Drift System - ADS, page 16).
NOTE: KL850GR instruments will default to Grade Mode when the instrument is turned on. The
Mode button is used for both selecting between the X-axis and Y-axis for setting grade and
exiting the Grade Mode (see Grade Mode — Dual or Single Axis Grade). Press and release
the Mode button to select between the X-axis and Y-axis when setting grade. To exit the
Grade Mode, press and hold the Mode button for 4 to 5 seconds, then release. This will
bring up the Mode Select Menu. The user can now toggle to other menu options. Pressing
the Mode button for 4 to 5 seconds and releasing is only required to exit the Grade Mode.
Leveling
1:
The instrument can stand alone on a level, sturdy surface or preferably secured to a 5⁄8-11
surveyor's tripod.
2:
Press the (A) button once, and allow time (up to 60 seconds) for the instrument to self-level.
NOTE: The laser head may begin to rotate before leveling is complete. The self-leveling speed is
approximately 1° per 4 seconds.
3:
After self-leveling, the instrument will begin operating in Rotation Mode.
NOTE: The KL850V, will return to last mode of operation (i.e. sweep, spot, or rotation speed);
however, does not retain grade information.
NOTE: After self-leveling, the instrument will begin operating in Rotation Mode for KL850, last selected
mode of operation (i.e. Sweep, Spot, Rotation Mode) for KL850V, and Grade Mode
for KL850GR.
Cross Axis Leveling (Models KL850V)
NOTE: ADS must be off to enable cross-axis leveling.
1.
Press the Manual mode (C) button once to enable cross-axis leveling. The instrument will level in
the x-axis only. The manual grade can be set in the y-axis only.
2.
Press the Manual mode (C) button again to shut off the cross-axis leveling and to place the
instrument into Manual mode.
NOTE: When the ADS is off, the remote Mode button will place the instrument in cross-axis leveling
with the first press and in Manual mode with the second press.
Plumbing / Lay-Down (Models KL850V)
1.
On a flat surface, place the instrument on its back using the built-in trivet (control panel
facing upward). (Fig. 7)
2.
Press the (A) button once, and allow time for the instrument to self-level.
NOTE:When the Instrument is placed in the laydown position, the ADS button (B) becomes the
Auto Beam Positioning button.
KL850 • KL850V • KL850GR • 13