Baumer PF55S Instrucciones De Servicio página 88

Sensor de caudal
Tabla de contenido

Publicidad

Función
FORCE AOUT1 4MA
FORCE AOUT1 20MA
FORCE AOUT2 4MA
FORCE AOUT2 20MA
AOUT DIAG BITS
FORCE SH HOLD
FORCE SH SAMPLE
SH DIAG BITS
FORCE INPUTS GND
FORCE INPUTS OPEN
INPUTS DIAG BITS
FORCE ADC GND
ADC DIAG BITS
DIAG MODE ACTIVE
FORCE AOUT 12MA
FORCE AOUT1 12MA
FORCE AOUT2 12MA
88
Descripción
FORCE ANALOG OUT TO 4 MA
VALUE
FORCE ANALOG OUT TO 20 MA
VALUE
FORCE ANALOG OUT TO 4 MA
VALUE
FORCE ANALOG OUT TO 20 MA
VALUE
DIAGNOSTIC BITS FOR AOUT
CONTROL
FORCE SAMPLE/HOLD TO HOLD
POSITION (SWITCHES OPEN)
FORCE SAMPLE/HOLD TO
SAMPLE POSITION (SWITCHES
CLOSE)
DIAGNOSTIC BITS FOR SAMPLE/
HOLD CONTROL
FORCE MEASURE INPUTS TO
GROUND
FORCE MEASURE INPUTS TO
OPEN (DISCONNECTED) STATE
DIAGNOSTIC BITS FOR MEASURE
INPUTS CONTROL
FORCE ADC MEASURE CHANNEL
TO GND
DIAGNOSTIC BITS FOR ADC CON-
TROL
DIAGNOSTIC MODE ACTIVE MASK
(ANY FUNCTION)
FORCE ANALOG OUT TO 12 MA
VALUE (GENERIC OUT 1)
FORCE ANALOG OUT TO 12 MA
VALUE (OUT 1)
FORCE ANALOG OUT TO 12 MA
VALUE (OUT 2)
Sensor de caudal PF55S
Guía de menú > Menú Diagnostic [diagnóstico]
Código
(decimal)
1048576
2097152
4194304
8388608
15728640
16777216
33554432
50331648
67108864
134217728
201326592
268435456
268435456
4294967295
3145728
3145728
12582912
Manejo
Código (hexade-
cimal)
100000
200000
300000
400000
00F00000
1000000
2000000
3000000
4000000
8000000
0C000000
10000000
10000000
FFFFFFFF
300000
300000
00C00000
05.03.2020

Publicidad

Tabla de contenido
loading

Tabla de contenido