Enermax Pro87+ Series Power Supply Specification - ENERMAX PRO87+ Manual Del Usuario

Tabla de contenido

Publicidad

ENERMAX PRO87+ Series Power Supply Specification

AC Input Voltage
AC Input Current
3.3V
5V
12V1
12V2
12V3
-12V
5Vsb
Total Power
Peak Power
Over Current Protection
Over Voltage Protection
(DC)
Under Voltage Protection
Over Power Protection
Over Temperature Protection
Short Circuit Protection
Surge & Inrush Protection
Temperature
Humidity
Cooling
MTBF
Dimension
Weight
Safety
EMC
EPG500AWT
(Maximum range:90-265VAC, 47-63Hz)
6.5 – 3A
DC OUTPUT
Rated
Combined
0-20A
100W
0-20A
0-25A
492W
0-25A
(41A)
0-25A
0-0.5A
6W
0-3A
15W
500W
550W
PROTECTION CIRCUIT
DC Rail
3.3V
5V
12V
DC Rail
3.3V
5V
12V
DC Rail
3.3V
5V
12V
Activated when output power > 120 ~150% of rated max load.
Activated when PSU heat sink > 90 ~ 120
Activated when any DC rails short-circuited.
Sustain 2KV surge stroke.
Sustain up to 70A inrush current @ 240VAC at cold start.
ENVIRONMENT
Operation ambient: 0~50
Storage ambient: -40~70
Operation: to 85% relative humidity, non-condensing at 25
Storage: to 95% relative humidity, non-condensing at 50
OTHERS
One 13.9cm two-ball bearing fan, speed auto controlled.
> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25
(MIL-HDBK-217F standard)
150 (w) x 86 (h) x 160 (d) mm
2.35kg ± 150g
UL/cUL(Level 6), TUV, GOST, CB, BSMI, CCC
CE, FCC, KCC
2
EPG600AWT
100-240VAC, 50-60Hz
8 – 3.5A
Rated
Combined
0-24A
120W
0-24A
0-25A
600W
0-25A
(50A)
0-25A
0-0.5A
6W
0-3A
15W
600W
660W
OCP trigger range
30 – 40A
30 – 40A
30 – 40A
OVP trigger range
3.7-4.1V
5.7-6.5V
13.1-14.5V
UVP trigger range
2.0 – 2.4V
3.3 – 3.7V
8.5 – 9.5V
o
C.
o
C (for full rated output)
o
C
EPG700AWT
9 – 4A
Rated
Combined
0-24A
120W
0-24A
0-25A
696W
0-25A
(58A)
0-25A
0-0.5A
6W
0-3A
15W
700W
770W
o
C
o
C
o
C

Publicidad

Tabla de contenido
loading

Tabla de contenido