3. Setting the multi view display
3-4. Setting the level meters
Level meters for the embedded audio signals transferred by
the SDI input can be displayed on the split screens.
Left display:
Channel 1 of group 1
Right display:
Channel 2 of group 1
[8] MultiView Out/Frame Menu
5. Level Meter
On: The level meters are displayed.
Off: The level meters are not displayed.
3-5. Setting the input signal marks
The status of the input signals can be displayed in front of
the material names displayed on the split screens.
"F" mark:
This appears when the input signals are frozen.
" ! " mark:
This appears when there are no input signals.
Camera icon "
":
This appears when the signals from a remote camera
controlled by the AW-RP50 are input.
It appears only when the unit and the AW-RP50 are
linked.
[8] MultiView Out/Frame Menu
6. Input Status
On: The input signal status is displayed.
Off: The input signal status is not displayed.