Step 4: Drill the holes.
Step 5: Hold the baseplate in the desired position and tighten it.
The installation material must never include abrading material e. g. steel cables in order to avoid
The length of the chain must never exceed 100 cm.
Install the mirrorball chain with the screw-on chain link at the installation eyelet of the mirrorball and tighten
the fixation screw.
Insert the fourth chain link of the mirrorball chain with the mirrorball in the screw-on chain link and tighten the
fixation screw.
For overhead use, always install a safety chain on the mirrorball that can hold at least 12 times the weight of
the installation. The safety chain must be slightly longer than the mirrorball chain so that the safety chain will
always be tension-free. Pull the safety chain through the safety eyelet of the mirrorball and in the safety
eyelet of the motor.
The maximum drop distance must never exceed 20 cm.
A safety chain which already held the strain of a crash or which is defective must not be used again.
There must never hang a mirrorball or other load at the safety eyelet. Loads must only be hanged at the
quick link of the installation eyelet at the motor axle. If a mirrorball hangs for any reason at the safety eyelet,
the motor must be taken out of operation immediately and the mirrorball must be uninstalled. The whole
installation has to be checked for defects by an expert.
Make sure that the rotation of the mirrorball is never slowed down or stopped by decoration material etc.
Make sure that no side forces can impact on the installation.
Make sure that the mirrorball cannot be moved by air streams. The mirrorball and the motor must be installed
and operated absolutely swivel free.
Please check in regular intervals, if the installation material (e. g. key ring, shackles or screw-on chain links)
or chain links have been deformed. Uninstall the mirrorball immediately in such a case.
Connection with the mains
Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
material wearing.
International
L
N
13/26
00026092.DOC, Version 2.0