direction - Fig.9.
• Tighten fittings, introduce the heat-shrinking hose C
and use a small heat source to warm it up. Make sure
that fittings are completely covered.
• Reconnect connectors A and B, screw in the handle M
and then the retention dowel G.
• Reposition the sleeve onto the handle and tighten the
clamp F1.
5.6 REPLACING
THE
ADAPTER.
J
P
AB
AC
W
CABLE
WITH
CENTRAL
T
X
M
I1
Y
Y1
Fig. 10
Fig. 7
Fig. 8
Fig. 9
Remove spring P and cut the clamps that fasten the cable
J. Open the cover W by unscrewing the 4 set screws and
then screw M. Remove pins of the control cable X and
Z. Take note of the position of each pin and then remove
the U-bolt T and the pins of the pilot arc red cables Y
and Y1. Cut the isolating hose K2 and unscrew body N
from fitting I1. Assemble the new fitting and follow the
previous instructions in reverse direction. Use thread
sealer to lock the N body thread. To avoid jeopardizing
the safety efficiency, the body contacts N must be
connected as follows: pins Y and Y1 of pilot arc red
cables to contacts 5 and 6, pin X of cable J to contact
1, pin Z of cable J to contact 9.
Z
N
Reconnect U-bolt T as described above.
5.7
WARNINGS
Periodically make sure that the welding torch cable is
intact and has no cuts or excessive wear. Replace it
immediately if needed.