New & Reconditioned Equipment & Parts- www.southeasternequipment.net
A - ENGLISH
AUTO-FILL
OPERATION:
Attach a 3/4" garden hose to the Auto-Fill Hose Connector (7), and connect the other end of the hose to your water source.
Make sure the fl oat that hangs from the auto fi ll valve into the tank is free of obstruction and can move freely.
Turn on the water supply. NOTE: Do not turn the water pressure on high; just turn the water on.
The auto-fi ll fl oat will automatically shut-off the fl ow of incoming water when the tank is nearly full, and it will allow the valve to open again once the
water level has dropped to a predetermined level.
AUTO-DUMP
OPERATION:
Before each use: Always use a clean pre-fi lter bag when operating the machine. If necessary, unscrew the stainless steel fi lter at the bottom of the
recovery tank and clean it. Also make sure the ball fl oat in the recovery tank is clean.
Attach a 3/4" garden hose to the Dump Hose Connection (18) on the dump pump on the back of the base of the machine.
Run the other end of the hose into a drain.
Turn ON the dump pump switch (F).
NOTE: The dump pump is 'self-priming.' You should see water start to fl ow within 30 seconds of the pump turning on. If water does not begin to
fl ow, check the fi lter to see if it is plugged with debris.
After each job: Run clear water though the dump pump to wash out any chemical residue. Remove and clean both the Pre-Filter Bag (27) and the
Pump Inlet Filter (26). Reinstall the fi lter once it is clean. Clean and empty the recovery tank.
DANGER!
Do NOT use solvents, or any chemicals that may be fl ammable, explosive or combustible.
CAUTION!
Always use a defoamer in the recovery tank to prevent water or foam from entering the vacuum motor.
DANGER!
Always unplug the MC1200 from the electrical outlet(s) before cleaning or maintaining. Certain internal components are electrically