PROTECTIVE FUNCTIONS OF THE RECEIVER
Lock protection- The DC motor has a built-in safety feature against blade or motor obstruction
during operation. If something obstructs the fan blades or motor, the motor will keep trying to run and
then stop operation after about 30 seconds of interruption. Please remove .
obstacles and reset. To reset: Turn the fan off by remote transmitter and then turn the fan on.
Over load protection (current limit)- The device will limit the maximum current output from the
receiver/drive if the fan load has increased abnormally.
Tips
1. If your fan is operates automatically after installation and power on, it is because your fan has
memorized the previous factory setting. Use the Universal Mode or the learning function and your
fan will be ready for use.
2. If the fan or light isn't working, reset power (turn the power off for at least 5 seconds and then turn the
power back on) and redo the learn function setting.
3.It is not possible to remotely operate more than one fan in the same room (in the area where the remote
signal can reach to) if they share the same power supply. Separate power supplies
(such as using individual wall switches for each fan) is required if you want to separately control more than
one fan in same room.
4. When the fan is turned on or operated using forward/reverse function, it shutters & goes back & forth
until it turns. This is a normal and it will take a few seconds to run this operation.
1. Periodic cleaning of your new ceiling fan is
the only maintenance that is needed.
2. When cleaning, use only a soft brush or lint
free cloth to avoid scratching the finish.
3. Abrasive cleaning agents are not required
and should be avoided to prevent damage
to finish.
RECOMMENDED:
Periodically check that the blade sets to the fan motor setscrews are secure and tight.
MAINTENANCE
Do not use solvents when cleaning your
ceiling fan. It could damage the motor
and create the possibility of electrical
shock.