DESCRIPTION
The HOROTEC
Flashtest is an advanced, multifunctional and portable tester for analog quartz watches and movements.
©
This handy, precision tester performs a variety of tests with both closed and open watchcases on analog quartz watches.
The HOROTEC
Flashtest can :
©
1. measure battery voltage from 0 to 19.99V
2. measure battery voltage under load from 0 to 19.99V
3. measure impulses from quartz watches to determine if a problem is electronic or mechanical
4. measure the continuity of the coil
5. measure the consumption of the electronic circuit to determine whether or not it needs replacement
6. measure the consumption of the movement to determine if there is any mechanical problem indicating the need
for cleaning or adjustment
7. measure the accuracy of the analogue quartz watches.
The HOROTEC
Flashtest is supplied with two precision probes, a 9V adaptor (input 220/110V AC - output 9V DC), a 9V
©
alkaline battery, an User's Manual and a Technical Guide, which contains the consumption and coil resistance data of the
most common quartz movements. (HOROTEC is a registered trademark in Switzerland, USA, EU and many other countries.)
CONNECTIONS
1. Battery : Open the battery cover on the rear side of the HOROTEC
battery as usual. Note: The battery should be replaced when a battery symbol appears on the LCD display of the
switched ON HOROTEC
2. AC adaptor : Plug in the AC adaptor power supply cord to mains (220V or 110V) as usual. Connect the 9V adaptor
male plug to rear jack of the HOROTEC
intensive use (watch repairers, after-sales services, quick battery change shops, watch manufacturers).
3. Probes : Connect the 2 probes plugs to rear side of the HOROTEC
red plug in the red terminal). The apparatus is provided with two (black and red) probe holders.
SPECIFICATIONS
A) QUICK TESTS WITH CLOSED WATCH CASE
HOROTEC
Flashtest has capabilities to perform quick tests of electronic watch parts (battery, electronic circuit, coil,
©
stepper motor) mechanical parts, by unjamming the wheel train (jammed from dust, dry oil or hands), hands and calendar
parts with closed watch case. Proceed to these tests when the watch is :
• new - before sale
• repaired - before to be returned to the customer
• damaged - for a quotation before the repairing.
Flashtest.
©
Flashtest. This action automatically disconnects the 9V battery for daily
©
Flashtest, and connect the attached 9V
©
Flashtest (black plug in the black terminal,
©
9