Technical Information
Model
*Wattage Voltage Amperage Phase
AT-S901-03 (3kW)
3 kW
AT-S901-13 (13kW) 13 kW
Minimum water flow to activate unit: 2.7 GPM
Nominal water volume: 0.11 gal (0.42l)
Working pressure: 0.5 -8 bar (7 -115 psi)
Tested pressure: 16 bar (230 psi)
Water connections: 1/2" NPT
Dimensions (in) (H x W x D): 9.05 x 11.4 x 4.33
Weight (Ib): 4.85- 5.29
* Wattage based on maximum voltage.
Model Guide - kW Output
Model
AT-S901-13 (13kW)
AT-S901-03 (3kW)
110
27
240
55
240V
208V
13.0 kW
9.8 kW
-
-
Circuit breaker
Required wire
size
1
30
1
60
110V
-
3.0 kW
size
10 AWG
4 AWG
120V
-
3.5 kW
2